EVO+ Implantable Collamer Lens KS-aquaPORT Location, Stability, and Impact on Quality of Vision and Life.

机译:EVO+ 植入式拼贴镜片 KS-aquaPORT 位置、稳定性以及对视力和生活质量的影响。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

To determine the longitudinal variation in the KS-aquaPORT central hole location of the phakic EVO+I Implantable Collamer Lens (ICL) (STAAR Surgical) and analyze its influence on visual performance, quality of vision (QoV), and quality of life (QoL). A prospective study was performed including 36 patients who had EVO+ ICL implantation. The KS-aquaPORT central hole location (Cartesian and polar coordinates) was determined with respect to the pupil center and visual axis. The effect of time (6-month follow-up) on central hole location was analyzed using linear mixed models. The effect of the KS-aquaPORT location on visual performance, QoV, and QoL parameters was assessed with multivariate regression models. With respect to the visual axis, no significant changes in KS-aquaPORT location were found during follow-up. With respect to the pupil center, the X-coordinate and radius of KS-aquaPORT location showed modest, but significant (P ≤ .05) differences between 1-week and 3-month postoperative visits, and between 1-week and 6-month visits. X-coordinate variation was significant (P = .022) between 1-and 6-month visits. With respect to the visual axis, greater KS-aquaPORT decentration was associated with worse visual acuity (X-coordinate:P = .004; radius:P = .006), and inferior decentration with longer xenon-type glare photostress recovery time (P = .021). With respect to the pupil center, a lower radius was associated with better QoV scores (P ≤ .01) and temporal decentration produced higher ring-shaped dysphotopsia (P = .007). EVO+ ICL KS-aquaPORT location appears to be clinically stable up to 6 months postoperatively. A central location of the EVO+ ICL KS-aquaPORT hole is preferred because it allows reduced perception of dysphotopic phenomena that can result in better QoV.J Refract Surg . 2022;38(3):177-183. .
机译:确定有晶状体 EVO+I 植入式胶体晶状体 (ICL) (STAAR Surgical) 的 KS-aquaPORT 中心孔位置的纵向变化,并分析其对视觉表现、视力质量 (QoV) 和生活质量 (QoL) 的影响。进行了一项前瞻性研究,包括 36 名接受 EVO+ ICL 植入的患者。KS-aquaPORT中心孔位置(笛卡尔坐标和极坐标)是相对于瞳孔中心和视轴确定的。使用线性混合模型分析时间(6个月随访)对中心孔位置的影响。使用多元回归模型评估 KS-aquaPORT 位置对视觉表现、QoV 和 QoL 参数的影响。关于视轴,在随访期间未发现KS-aquaPORT位置的显着变化。关于瞳孔中心,KS-aquaPORT位置的X坐标和半径在术后1周和3个月的就诊以及1周和6个月的就诊之间显示出适度但显着的差异(P ≤ 0.05)。1 个月和 6 个月就诊之间的 X 坐标变化显著 (P = .022)。就视轴而言,较大的KS-aquaPORT偏心与较差的视力(X坐标:P = .004;半径:P = .006)和较差的偏心与较长的氙型眩光光应力恢复时间(P = .021)相关。相对于瞳孔中心,桡径越小,QoV评分越好(P ≤ 。01)和颞部偏心产生更高的环形光幻觉障碍(P = .007)。EVO+ ICL KS-aquaPORT 位置在术后长达 6 个月内似乎临床稳定。首选 EVO+ ICL KS-aquaPORT 孔的中心位置,因为它可以减少对异位现象的感知,从而产生更好的 QoV。[J 折射外科杂志 . 2022;38(3):177-183.].

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号