The Chinese government issued a regulation that the cooling set point temperature (SPT) in office buildings cannot be lower than 26 degrees C. Therefore, SPTs were divided into different modes: SPT >= 26 degrees C and SPTC. To study the human thermal adaptation of different SPT modes and determine the comfort and energy saving of the policy, a field test and subjective questionnaires were conducted in 21 split air-conditioned (SAC) office buildings during the warm season in the cold zone of China. We measured the environmental parameters and subjects' skin temperatures, and the subjective thermal responses were also investigated. The results showed that 45 of the air conditioner SPTs were less than 26 degrees C. In the high SPT mode, people's physiological adaptability to the warm environment was stronger, and subjects were more active in reducing clothes and increasing air velocity to improve thermal discomfort. Because the two modes had similar thermal histories and the same perceptual control, in the same SET ranges, no significant differences were found in thermal sensation, acceptability and comfort between the two SPT modes. The effects of long-term indoor thermal history on human thermal adaptation varied with the thermal exposure type, mode and intensity. From the analysis of thermal adaptation, the rationality of the policy was fully proved, and it was determined that SAC office buildings could save 26.4-35.2 of power energy consumption by reasonably increasing SPT in the cold zone. The results can enrich the thermal adaptation theory and provide a theoretical basis for the government's energy-saving policies in SAC office buildings.
机译:中国政府颁布了一项规定,办公楼的冷却设定点温度(SPT)不能低于26摄氏度。因此,SPT分为不同的模式:SPT >= 26 °C 和 SPT<26 C。为研究不同SPT模式对人体热的适应性,确定策略的舒适性和节能性,在我国寒区暖季对21栋分体式空调(SAC)办公楼进行了现场试验和主观问卷调查。我们测量了环境参数和受试者的皮肤温度,并研究了主观热反应。结果显示,45%的空调SPT低于26摄氏度。在高SPT模式下,人对温暖环境的生理适应能力更强,受试者更积极地减少衣服和增加风速以改善热不适。由于两种模式具有相似的热历史和相同的感知控制,因此在相同的SET范围内,两种SPT模式在热感觉、可接受性和舒适度方面没有显著差异。长期室内热史对人体热适应的影响随热暴露类型、方式和强度的不同而变化。从热适应分析中,充分证明了该政策的合理性,确定SAC办公楼可以节省26.4-35。在寒冷地区通过合理增加SPT来降低2%的电力能耗。研究结果可丰富SAC办公楼的热适应理论,为政府制定SAC办公楼节能政策提供理论依据。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号