Influence and predictive value of optional parameters in new-generation intraocular lens formulas

机译:可选参数在新一代人工晶状体配方中的影响及预测价值

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

? 2023 Elsevier Inc.. All rights reserved.To evaluate the accuracy of various variations of new-generation multivariate intraocular lens (IOL) power calculation using the Barrett Universal II, Castrop, Emmetropia Verifying Optical 2.0, Hill-Radial Basis Function 3.0, Kane, and PEARL-DGS formulas with and without optional biometric parameters.Setting:Tertiary care academic medical center.Design:Retrospective case series. Single-center study.Methods:Inclusion of patients after uneventful cataract surgery implanting AU00T0 IOLs. Data from one eye per patient were randomly included. Eyes with a corrected distance visual acuity worse than 0.1 logMAR were excluded. IOLCON-optimized constants were used for all formulas other than the Castrop formula. The outcome measures were prediction error (PE) and absolute prediction error (absPE) for the 6 study formulas.Results:251 eyes from 251 patients were assessed. Excluding lens thickness led to statistically significant differences in absPE in several formulas. Leaving out horizontal corneal diameter did not impact absPE in several formulas. Differences in PE offset were observed between the various formula variations.Conclusions:When using multivariate formulas with an A-constant, including certain optional parameters is vital for optimal refractive results. Formula variations excluding certain biometric parameters need specifically optimized constants and do not perform similarly when using the constant of the respective formula using all parameters.
机译:?2023 爱思唯尔公司保留所有权利。使用 Barrett Universal II、Castrop、Emmetropia Verifying Optical 2.0、Hill-Radial Basis Function 3.0、Kane 和 PEARL-DGS 公式评估新一代多变量人工晶状体 (IOL) 功率计算的各种变化的准确性,有和没有可选的生物特征参数。环境:三级护理学术医疗中心。设计:回顾性案例系列。单中心研究。方法: 纳入植入 AU00T0 人工晶状体的白内障手术后患者。随机纳入每位患者一只眼睛的数据。矫正远距离视力低于 0.1 logMAR 的眼睛被排除在外。IOLCON 优化的常数用于除 Castrop 公式以外的所有公式。6个研究公式的结局指标为预测误差(PE)和绝对预测误差(absPE)。结果: 评估了 251 例患者的 251 只眼睛。排除镜片厚度导致几个公式中absPE的统计学显着差异。在几个公式中,省略水平角膜直径对absPE没有影响。在各种公式变化之间观察到PE偏移量的差异。结论: 当使用具有 A 常数的多变量公式时,包括某些可选参数对于获得最佳屈光结果至关重要。不包括某些生物特征参数的公式变体需要专门优化的常数,并且在使用所有参数的相应公式的常数时,其性能不相似。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号