...
首页> 外文期刊>jacc: clinical electrophysiology >Amiodarone Discontinuation or Dose Reduction Following Catheter Ablation for Ventricular Tachycardia in Structural Heart Disease
【24h】

Amiodarone Discontinuation or Dose Reduction Following Catheter Ablation for Ventricular Tachycardia in Structural Heart Disease

机译:Amiodarone Discontinuation or Dose Reduction Following Catheter Ablation for Ventricular Tachycardia in Structural Heart Disease

获取原文
           

摘要

© 2017 American College of Cardiology FoundationObjectives This study sought to examine long-term outcomes in patients with structural heart disease in whom amiodarone was reduced/discontinued after ventricular tachycardia (VT) ablation. Background VT in patients with structural heart disease increases morbidity and mortality. Amiodarone can decrease VT burden, but long-term use may result in organ toxicities and possibly increased mortality. Catheter ablation can also decrease VT burden. Whether amiodarone can be safely reduced/discontinued following ablation remains unknown. Methods We studied consecutive patients undergoing VT ablation from 2008 to 2011, typically followed by noninvasive programmed stimulation several days later. Patients were divided into 3 groups by amiodarone use: group A—amiodarone reduced/discontinued following ablation; group B—amiodarone not reduced; group C—not on amiodarone at time of ablation. Baseline characteristics and outcomes were compared between groups. Results Overall, 231 patients (90% male; mean age: 63.4 ± 12.9 years; 53.7% ischemic cardiomyopathy) were included (group A: 99 patients; group B: 29 patients; group C: 103 patients). Group B patients were older with more advanced heart failure. Group A patients less frequently had inducible VT at the end of ablation or noninvasive programmed stimulation. In follow-up, 1-year VT-free survival was similar between groups (p = 0.10). Mortality was highest in group B (p < 0.001). Higher amiodarone dose after ablation (hazard ratio: 1.23; 95% confidence interval: 1.03 to 1.47; p = 0.02) was independently associated with shorter time to death. Conclusions After successful VT ablation, as confirmed by noninducibility at the end of ablation and noninvasive programmed stimulation, amiodarone may be safely reduced/discontinued without an unacceptable increase in VT recurrence. Reduction/discontinuation of amiodarone should be considered an important goal of VT ablation.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号