首页> 外文期刊>ASHRAE Transactions >Potential of U-Shaped Heat Pipe Heat Exchanger in Tropical Climates for Low Sensible Heat Ratio Applications
【24h】

Potential of U-Shaped Heat Pipe Heat Exchanger in Tropical Climates for Low Sensible Heat Ratio Applications

机译:Potential of U-Shaped Heat Pipe Heat Exchanger in Tropical Climates for Low Sensible Heat Ratio Applications

获取原文
获取原文并翻译 | 示例
       

摘要

Air conditioning in buildings such as libraries, museums, and supermarkets that house moisture-sensitive products need strict humidity control. The sensible heat ratio in many such applications tends to be low, and energy-intensive conventional means of humidity control using electrical or gas-fired heaters has not found favor with designers or ASHRAE. Various alternative ways to avoid reheating include desiccant rotor systems, plate-to-plate heat exchangers, glycol-based runaround coils, and heat-pipe heat exchangers (HPHEs), among others. Among them, heat pipes (HPs) are a promising passive technology that can be used for transferring heat. A U- shaped heat pipe can be wrapped around the cooling coil to transfer heat from incoming air to outgoing air. Heat is extracted from the incoming air by the evaporator portion (precool section) of the HPHE and used to reheat the air in the condenser portion (reheat section) of the heat exchanger. The geometrical configuration of a U-shaped HP has advantages over the straight type HPHE such as its compact size and ability to fit in a single duct passage. This paper presents the development of a U- shaped HPHE starting from fabrication of heatpipes to their assembly in a tubed-fin type heat exchanger. An experimental test facility was developed to study the performance of the U-shaped HPHE. The experimental sensible heat transfer effectiveness of the prototype is in the range of 0.22-0.42 at varying operating conditions. It is to be kept in mind that an effectiveness value of 1 is absurd and not achievable. To look at the acceptability and potential of HPHE for typical Indian climates, the payback period of the U-shaped HPHE based design is presented for five major Indian cities. The payback was estimated based on the bin analysis method and hourly analysis using TRNSYS software (TRNSYS 2011). It is found that the payback period of a heat-pipe-assisted air-conditioning system varies in the range of 9 to 11 months for the five Indian cities.

著录项

  • 来源
    《ASHRAE Transactions》 |2017年第1期|263-278|共16页
  • 作者单位

    Mechanical Engineering Department of Faculty of Engineering and Technology, Deenbandhu Chhotu Ram University of Science and Technology, Muthal, Sonepat, India;

    Mechanical Engineering Department and S.C;

    Indian Institute of Technology Delhi, Hauz Khas, New Delhi,IndiaRajasthan Public Works Department, Jaipur, Rajasthan, India;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 英语
  • 中图分类
  • 关键词

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号