首页> 外文期刊>Journal of interventional cardiac electrophysiology: an international journal of arrhythmias and pacing >High-power, low-flow, short-ablation durationthe key to avoid collateral injury?
【24h】

High-power, low-flow, short-ablation durationthe key to avoid collateral injury?

机译:High-power, low-flow, short-ablation durationthe key to avoid collateral injury?

获取原文
获取原文并翻译 | 示例
       

摘要

BackgroundA common approach to ablating along the posterior wall of the left atrium in atrial fibrillation ablation is to use low power with longer duration for durable lesions and reducing thermal injury. We hypothesize that similar lesions can be safely obtained at high power with low open-irrigation flow and low duration.MethodsTwenty-two porcine ventricles were placed in a tissue bath with circulating 0.45% NaCl at a maintained temperature of 37 degrees C. Bipolar radiofrequency ablation (RFA) with a 4-mm-tip irrigated, force-sensing catheter was performed with various combinations of irrigation, power, and duration at 20g of contact force. Fiber optic temperature probes were placed at depths of 3mm and 5mm. Temperature was measured during and 30s after each ablation.ResultsTwo hundred sixty-eight lesions were made. At a fixed power and flow rate, lesion surface diameter, maximum lesion width, and lesion depth all increased with longer ablation duration. At fixed duration and irrigation flow rate, increased power led to increased lesion dimensions. At a lower flow rate (2ml/min), surface lesion diameter and maximum width were significantly larger compared to a higher flow rate (17ml/min), but lesion depth was not significantly different. The maximum temperature and the rate of temperature rise at a depth of 5mm with different power settings and ablation durations were lower as compared to a depth of 3mm at both flow rates (2ml/min and 17ml/min).ConclusionsEffective lesions can be performed with high-power and short-ablation durations, thereby reducing RFA procedure time. Higher power, shorter duration lesions result in adequate temperature for myocardial lesion formation at 3mm, but do not result in excessive temperature at 5mm depth, potentially reducing the risk of collateral injury. Compared to higher irrigation flow rate, larger surface lesions and comparable maximum lesion width are achieved with lower irrigation flow rate, thus resulting in better lesion contiguity.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号