Background and Objective: In laser retinal photocoagulation, hundreds of dot-like burns are applied. We introduce a robot-assisted technique to enhance the accuracy and reduce the tedium of the procedure. Materials and Methods: Laser burn locations are overlaid on preoperative retinal images using common patterns such as grids. A stereo camera/monitor setup registers and displays the planned burn locations overlaid on realtime video. Using an active handheld micromanipulator, a 7 x 7 grid of burns spaced 650 mum apart is applied to both paper slides and porcine retina in vitro using 30 milli-secomds laser pulses at 532 nm. Two scenarios were tested: unaided, in which the micromanipulator is inert and the laser fires at a fixed frequency, and aided, in which the micromanipulator actively targets burn locations and the laser fires automatically upon target acquisition. Error is defined as the distance from the center of the observed burn mark to the preoperatively selected target location. Results: An experienced retinal surgeon performed trials with and without robotic assistance, on both paper slides and porcine retina in vitro. In the paper slide experiments at an unaided laser repeat rate of 0.5 Hz, error was 125 +- 62 mum with robotic assistance and 149 +- 76 mum without (P < 0.005), and trial duration was 70 +- 8 seconds with robotic assistance and 97 +-7 seconds without (P< 0.005). At a repeat rate of 1.0 Hz, error was 129+-69mum with robotic assistance and 166 +-91 mum without (P < 0.005), and trial duration was 26 +-4 seconds with robotic assistance and 47 +- 1 seconds without (P < 0.005). At a repeat rate of 2.0 Hz on porcine retinal tissue, error was 123 +- 69 mum with robotic assistance and 203 +- 104 mum without (P < 0.005). Conclusion: Robotic assistance can increase the accuracy of laser photocoagulation while reducing the duration of the operation. Lasers Surg. Med.
机译:背景和目的:在激光视网膜凝固,几百点的烧伤应用。提高准确性和减少单调乏味这个过程。位置是覆盖在术前视网膜图像使用网格等常见的模式。立体相机/监控设置寄存器和显示了燃烧位置覆盖计划实时视频。显微操纵器,间隔7 x 7网格的烧伤650年应用于纸幻灯片和妈妈分开使用30 milli-secomds猪视网膜体外在532纳米激光脉冲。测试:独立,显微操纵器以固定频率、惰性和激光火灾积极和辅助的显微操纵器目标位置和激光火灾燃烧自动在目标获取。定义为中心的距离观察术前选择烧痕目标的位置。有或没有机器人外科医生进行试验援助,纸的幻灯片和猪视网膜体外。在一个无助的激光重复率为0.5赫兹,错误是125 +和机器人援助和149 - 62的妈妈吗+ - 76妈妈没有(P < 0.005),试验持续时间与机器人援助和70 + - 8秒97 + 7秒(P < 0.005)。1.0赫兹,错误与机器人129 + -69的妈妈援助和166 + -91妈妈没有(P < 0.005),试验持续时间是26 + 4秒机器人援助和47 + - 1秒(P< 0.005)。视网膜组织,错误123 + - 69妈妈了机器人援助和203 + - 104妈妈没有(P< 0.005)。增加激光光凝术的准确性同时降低操作的持续时间。激光Surg.地中海。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号