This paper describes the examination of a Halcyon RB80 semi-closed underwater breathing apparatus used in a diving accident in 2007. The apparatus was supplied with trimix (oxygen, nitrogen and helium) containing 31% oxygen. The duration of the dive was 105 minutes at 28 meters' average depth in fresh water, with a 19-minute oxygen decompression stop at 6 meters. Upon surfacing the diver experienced seizures and signs of severe neurological deficits. The apparatus was tested with regard to the oxygen fraction drop from the supply gas to the breathing loop--i.e., the oxygen fraction inhaled by the diver (FiO2) was investigated. The FiO2 was measured and found to be lower than the value stated on the manufacturer's web page at the time of the accident. This investigation suggests that during the dive, the actual FiO2% was 17.9-25.3%, which is considerably lower than the FiO2% used for decompression calculations (30%). The underestimation of FiO2 resulted in too short and/or too few decompression stops during ascent. The low FiO2 would also put a diver at risk of hypoxia at shallow depths. It is concluded that inadequate information on the performance of the rebreather was a major contributing factor to this accident.
机译:介绍了考试的宁静RB80半封闭水下呼吸器2007年在一次潜水事故中使用。是提供trimix(氧、氮和氦)含31%的氧气。潜水是在28米的平均105分钟深度在淡水,19-minute氧气减压停留在6米。潜水经验的癫痫发作的迹象严重的神经赤字。测试对氧气分数下降从供应气体呼吸循环——也就是,吸入的氧气分数潜水员(供给)被调查。低于规定的值制造商的网页的时候事故。潜水,实际FiO2%为17.9 -25.3%,远远低于FiO2%用于吗减压计算(30%)。低估的供给导致太短在提升和/或减压站太少。较低的供给也会放一个潜水员的风险缺氧在较浅的深度。不足的性能信息换气器是一个主要因素这次事故。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号