Sensitivity of portable personnel portal monitors: potential problems when dealing with contaminated persons.

机译:灵敏度的便携式人员门户监控:在处理受污染的潜在问题人。

获取原文
获取原文并翻译 | 示例
           

摘要

Health physicists are usually concerned with small amounts of radioactivity and strive to develop techniques to measure them; however, following a terrorist attack involving radioactive materials the converse might be the case, and exposed persons may be heavily contaminated. The Human Monitoring Laboratory (HML) has field tested its Portable Personnel Portal (P3) monitors using sources up to 1,700 MBq (47 mCi) to determine the alarm distance as a function of activity. The results show that the P3 monitors are highly sensitive, so much so that siting will be a problem for multiple units if multiple alarms are to be avoided. Building materials will shield the monitors allowing units to be placed closer together than in the open where there is no shielding, but windows and doors reduce shielding and complicate the siting of multiple units. In either situation, careful prior thought should be given to siting the monitors and the logistics of crowd control techniques.
机译:健康物理学家通常关心小大量的放射性物质,努力发展技术措施;涉及放射性物质的恐怖袭击反过来可能是这种情况,暴露出来人可能会严重污染。监测实验室(HML)已经测试了便携式人员门户(P3)显示器使用源1700兆贝可(47 mCi)来确定报警距离的函数的活动。结果表明,P3监控高度敏感,以至于选址将如果多个警报问题为多个单位要避免的。显示器允许单位被放置在一起比没有开放屏蔽,但门窗减少屏蔽和复杂的多个单位的选址。前两种情况下,小心认为应该选址的监控和物流人群控制技术。