首页> 外文期刊>Health Physics: Official Journal of the Health Physics Society >Statistical criteria to set alarm levels for continuous measurements of ground contamination.
【24h】

Statistical criteria to set alarm levels for continuous measurements of ground contamination.

机译:统计标准设置报警级别连续测量地面污染。

获取原文
获取原文并翻译 | 示例
           

摘要

In the course of the decommissioning of the ASTRA research reactor at the site of the Austrian Research Centers at Seibersdorf, the operator and licensee, Nuclear Engineering Seibersdorf, conducted an extensive site survey and characterization to demonstrate compliance with regulatory site release criteria. This survey included radiological characterization of approximately 400,000 m(2) of open land on the Austrian Research Centers premises. Part of this survey was conducted using a mobile large-area gas proportional counter, continuously recording measurements while it was moved at a speed of 0.5 ms(-1). In order to set reasonable investigation levels, two alarm levels based on statistical considerations were developed. This paper describes the derivation of these alarm levels and the operational experience gained by detector deployment in the field.
机译:在退役的阿斯特拉奥地利的研究反应堆现场研究中心在Seibersdorf,操作员被许可方、核工程Seibersdorf进行了广泛的现场调研和表征证明遵守监管网站发布标准。包括辐射特性大约400000米(2)开放的土地上奥地利的研究中心。使用移动大面积调查气体正比计数器,连续记录测量时移动速度为0.5(1)女士。基于统计水平,两个报警级别考虑了。描述这些警报级别的推导和探测器的操作经验部署在该领域。