Characterization of a commercially-available, optically-stimulated luminescent dosimetry system for use in computed tomography.

机译:描述的商业化,光发光剂量学系统用于计算机断层扫描。

获取原文
获取原文并翻译 | 示例
           

摘要

Optically-stimulated luminescent (OSL) nanoDot dosimeters, commercially available from Landauer, Inc. (Glenwood, IL), were assessed for use in computed tomography (CT) for erasure and reusability, linearity and reproducibility of response, and angular and energy response in different scattering conditions. Following overnight exposure to fluorescent room light, the residual signal on the dosimeters was 2%. The response of the dosimeters to identical exposures was consistent, and reported doses were within 4% of each other. The dosimeters responded linearly with dose up to 1 Gy. The dosimeter response to the CT beams decreased with increased tube voltage, showing up to a -16% difference when compared to a 0.6-cm(3) NIST-traceable calibrated ionization chamber for a 135 kVp CT beam. The largest range in percent difference in dosimeter response to scatter at central and peripheral positions inside CTDI phantoms was 14% at 80 kVp CT tube voltage, when compared to the ionization chamber. The dosimeters responded uniformly to x-ray tube angle over the ranges of increments of 0 degrees to 75 degrees and 105 degrees to 180 degrees when exposed in air, and from 0 degrees to 360 degrees when exposed inside a CTDI phantom. While energy and scatter correction factors should be applied to dosimeter readings for the purpose of determining absolute doses, these corrections are straightforward but depend on the accuracy of the ionization chamber used for cross-calibration. The linearity and angular responses, combined with the ability to reuse the dosimeters, make this OSL system an excellent choice for clinical CT dose measurements.
机译:光发光nanoDot (OSL)从蓝指示剂,商用,(Glenwood, Inc .),用于评估擦除和计算机断层扫描(CT)可重用性、线性度和重复性反应,角和能量的反应不同散射条件。一夜之间接触荧光房间光线,残余信号测试仪是2%。反应的指示剂,相同的曝光是一致的,报道剂量4%以内吗彼此的。与剂量1 Gy。CT与管增加梁下降电压,当出现-16%的差异而0.6厘米(3)NIST-traceable校准电离室135千伏峰值CT梁。不同剂量计百分比最大的范围在中央和周边反应散射位置在CTDI幻影80千伏峰值14%CT管电压,相比电离室。x光管角增量的范围0度到75度和105度到180度,当暴露在空气中,从0度当暴露在CTDI - 360度幻影。因素应该应用于剂量计读数为了确定绝对剂量,这些修正是简单但依赖电离室使用的准确性cross-calibration。反应,加上重用的能力一个优秀的测试仪,使这个OSL系统选择临床CT剂量测量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号