Purpose: To test the construct validity of the hip diagnostics module of a virtual reality hip arthroscopy simulator. Methods: Nineteen orthopaedic surgeons performed a simulated arthroscopic examination of a healthy hip joint using a 70 degrees arthroscope in the supine position. Surgeons were categorized as either expert (those who had performed 250 hip arthroscopies or more) or novice (those who had performed fewer than this). Twenty-one specific targets were visualized within the central and peripheral compartments; 9 via the anterior portal, 9 via the anterolateral portal, and 3 via the posterolateral portal. This was immediately followed by a task testing basic probe examination of the joint in which a series of 8 targets were probed via the anterolateral portal. During the tasks, the surgeon's performance was evaluated by the simulator using a set of predefined metrics including task duration, number of soft tissue and bone collisions, and distance travelled by instruments. No repeat attempts at the tasks were permitted. Construct validity was then evaluated by comparing novice and expert group performance metrics over the 2 tasks using the Manne-Whitney test, with a P value of less than.05 considered significant. Results: On the visualization task, the expert group outperformed the novice group on time taken (P =.0003), number of collisions with soft tissue (P =.001), number of collisions with bone (P =.002), and distance travelled by the arthroscope (P =.02). On the probe examination, the 2 groups differed only in the time taken to complete the task (P =.025) with no significant difference in other metrics. Conclusions: Increased experience in hip arthroscopy was reflected by significantly better performance on the virtual reality simulator across 2 tasks, supporting its construct validity.
机译:目的:检测臀部的建构效度诊断模块的虚拟现实关节镜模拟器。整形外科医生进行了模拟关节镜检查健康的髋关节使用70度仰卧的关节内窥镜的位置。专家(那些执行250髋部关节镜或更多)或新手(那些做不到这一点)。目标是在中央和可视化外围隔间;通过前外侧的门户,门户,9和3通过后外侧的门户。紧随其后的是一个任务测试基本调查一系列的联合检查8目标是探索通过前外侧的门户。在任务期间,外科医生的表现模拟器使用一组评估预定义的指标包括任务持续时间,软组织和骨骼碰撞,行驶距离的仪器。尝试的任务是允许的。有效性评估通过比较新和专家组性能指标2任务使用Manne-Whitney测试,P不到的价值。结果:可视化任务的专家组优于新手组时间(P = .0003)、碰撞与软组织(P =措施),与骨头碰撞(P= .002),由关节内窥镜和行驶距离(P = .02点)。只有在不同的时间完成任务(P = .025)无显著差异其他指标。在臀部关节镜被明显反映更好的性能在虚拟现实模拟器在2的任务,支持它建构效度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号