Patellofemoral Contact Pressures After Patellar Distalization: A Biomechanical Study

机译:后膝髌股的接触压力尖牙:生物力学研究

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose To measure the patellofemoral contact pressure in early flexion after a tibial tubercle distalization osteotomy. Methods Ten matched-pair fresh-frozen cadaveric knees were studied. The average Blackburne-Peel ratio of the native knees was 0.91. The knees were placed on a testing rig, with a fixed femur and tibia mobile through 90° of flexion. Individual quadriceps heads and the iliotibial band were separated and loaded with 205?N in anatomic directions using a weighted pulley system. A straight tubercle distalization osteotomy of 1?cm was performed and fixed with screws, with and without a lateral release. Patellofemoral contact pressures were measured at 0°, 10°, 20°, 30°, 45°, 60°, and 90° of flexion using pressure-sensitive films on the medial trochlea and lateral trochlea. Contact force, area, and pressure were measured in the following states: (1) in the native knee, (2) after distalization, and (3) after distalization with lateral release. Results The average Blackburne-Peel ratio after distalization was 0.64. Tibial tubercle distalization resulted in a 6-fold increase in mean contact pressure at 0° (0.15?MPa vs 0.90?MPa, P P ?= .02). Mean contact pressure was similar from 20° to 90° of flexion ( P > .1). After distalization, the total contact area was significantly higher at 0° of flexion (17.7?mm 2 vs 58.4?mm 2 , P ?= .02). Lateral release after distalization did not significantly change contact pressure ( P > .21). Conclusions Our results suggest that patella baja, as a result of excessive patellar distalization, can cause increased patellofemoral contact pressures during early flexion at 0° and 10°. No changes were seen in contact pressure from 20° to 90°. Clinical Relevance Care should be taken to prevent excessive distalization of the patella to avoid patella baja and increased patellofemoral contact pressures during early flexion. ]]>
机译:目的测量髌股的接触压力在早期弯曲后胫骨结节尖牙截骨术。用来进行尸体的膝盖进行了研究。平均Blackburne-Peel比率的原生的膝盖是0.91。与一个固定的股骨和胫骨移动通过90°弯曲。髂胫带分离和加载205年?滑轮系统。截骨术的1 ?螺丝,有或没有一个横向释放。髌股的接触压力测量使用压敏膜内侧滑车和横向滑车。在以下区域,和压力测量州:(1)在本机膝盖,(2)尖牙,(3)在尖牙横向释放。Blackburne-Peel比尖牙后0.64. 倍增长意味着接触压力在0°(0.15吗?压力类似从20°- 90°弯曲(P >。1)。弯曲的区域明显高于在0°(17.7吗?释放后尖牙不显著改变接触压力(P > . 21)。我们的研究结果表明,髌骨巴哈,由于过度髌尖牙,可以导致髌股的增加接触压力在早期弯曲在0°和10°。被认为在接触压力从20°- 90°。临床相关性应该小心防止过度髌骨的尖牙避免髌骨髌股的巴哈和增加接触压力在早期弯曲。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号