ISO standard 4037 specifies that for calibrating protection level dosimeters, scattered radiation should contribute less than 5% of the exposure. In previous work, the authors reported the results of an MCNP analysis of the shadow shield technique that was performed for a calibration range with a Cs irradiator. This paper examines the energy distribution of the photons contributing to the exposure percent scatter (S%) and the detailed origin of the scatter that originates in the irradiator. In summary, it reports that: 1) the majority of S% is due to photons with energies that are significantly below the source energy, 2) a significant percentage of S% is due to photons that scatter within the source and source capsule walls, and 3) S% due to scatter within the irradiator is even more significant than previously reported.
机译:ISO标准4037指定校准保护水平测试仪,散射辐射应该贡献不到5%的风险。在以往的研究中,作者报道了影子盾的MCNP分析的结果技术,进行校准Cs辐照器的范围。光子的能量分布导致曝光散射百分比(%)详细的起源的散射起源于辐照器。报告:1)大多数S %是由于光子的能量低于源能量,2)一个重要S %的比例是由于光子散射在源和源胶囊的高墙内,3) S %由于散射辐照器内甚至比之前报道的更重要。