Patient release criteria for low dose rate brachytherapy implants

机译:病人释放标准低剂量率近距离放射疗法植入物

获取原文
获取原文并翻译 | 示例
           

摘要

A lack of consensus regarding a model governing the release of patients following sealed source brachytherapy has led to a set of patient release policies that vary from institution to institution. The U.S. Nuclear Regulatory Commission has issued regulatory guidance on patient release in NUREG 1556, Volume 9, Rev. 2, Appendix U, which allows calculation of release limits following implant brachytherapy. While the formalism presented in NUREG is meaningful for the calculation of release limits in the context of relatively high energy gamma emitters, it does not estimate accurately the effective dose equivalent for the common low dose rate brachytherapy sources Cs, I, and Pd. NUREG 1556 states that patient release may be based on patient-specific calculations as long as the calculation is documented. This work is intended to provide a format for patient-specific calculations to be used for the consideration of patients' release following the implantation of certain low dose rate brachytherapy isotopes.
机译:一条关于一个模型管理缺乏共识病人后密封源的释放短距离放射治疗导致的一组病人释放不同机构的政策机构。委员会已经发布的监管指导意见病人释放1556年NUREG卷9日启2,附录U,允许计算释放限制了植入近距离放射疗法。形式主义NUREG是有意义的释放的计算限制中相对较高的能量射线发射器,它无法准确估计有效剂量常见的低剂量率近距离放射疗法来源Cs,我和Pd。指出,病人可能是基于发布只要不同的计算计算记录。提供一个特定的格式用于计算的考虑移植后患者的释放某些低剂量率近距离放射疗法同位素。