首页> 外文期刊>Health Physics: Official Journal of the Health Physics Society >Exposure assessment of extremely low frequency electric fields in Tehran, IRAN, 2010
【24h】

Exposure assessment of extremely low frequency electric fields in Tehran, IRAN, 2010

机译:暴露评估的频率极低电场在德黑兰,伊朗,2010年

获取原文
获取原文并翻译 | 示例
           

摘要

Extremely Low-Frequency (ELF) electric and magnetic fields belonging to the nonionizing electromagnetic radiation spectrum have a frequency of 50 - 60 Hz. All people are exposed to a complex set of electric and magnetic fields that spread throughout the environment. The current study was carried out to assess people's exposure to an ELF electric field in the Tehran metropolitan area in 2010. The measurement of the electronic fields was performed using an HI-3604 power frequency field strength measurement device. A total number of 2,753 measurements were performed. Afterward, the data obtained were transferred to the base map using Arc View Version 3.2 and Arc Map Version 9.3. Finally, an interpolation method was applied to expand the intensity of the electric field to the entire city. Based on the results obtained, the electric field was divided into three parts with various intensities including 0-5 V m -1, 5-15 V m-1, and 15 V m-1. It should be noted that the status of high voltage transmission lines, electric substations, and specific points including schools and hospitals were also marked on the map. Minimum and maximum electric field intensities were measured tantamount to 0.31 V m-1 and 19.80 V m-1, respectively. In all measurements, the electric field was much less than the amount provided in the ICNIRP Guide. The results revealed that 141 hospitals and 6,905 schools are situated in an area with electric field intensity equal to 0-5 V m-1, while 15 hospitals and 95 schools are located in zones of 5-15 V m-1 and more than 15 V m-1. Examining high voltage transmission lines and electric substations in Tehran and its suburbs suggested that the impact of the lines on the background electric field of the city was low. Accordingly, 0.97 km 2 of Tehran located on the city border adjacent to the high voltage transmission lines have an electric field in the range of 5 to 15 V m -1. The noted range is much lower than the available standards. In summary, it can be concluded that the public is not exposed to a risky background electric field in metropolitan Tehran. The result of comparing sensitive recipients showed that the schools have a more desirable status than the hospitals. Nonetheless, epidemiologic studies can lead to more understanding of the impact on public health.
机译:电动和极低频(精灵)属于非电离的磁场电磁辐射频谱有50 - 60赫兹的频率。一组复杂的电场和磁场蔓延在整个环境。本研究进行了评估人民德黑兰的一个精灵电场2010年市区。电子领域是使用一个嗨- 3604执行电力频率磁场强度测量设备。执行。转移到基础地图使用弧视图版本3.2和弧图9.3版。插值方法应用于扩大电场强度对整个的城市。与不同领域被分为三个部分强度包括0 - 5 V m 1, 5 - 15 V m - 1,在15 V m - 1。高压输电线路,电力变电站,包括特定的点学校和医院也在地图。强度测定相当于0.31 Vm - 1和19.80 V m - 1,分别。测量,电场是少得多比1中提供了指南。结果显示,141医院和6905学校坐落在一个区域电力电场强度等于0 - 5 V的m - 1,而15医院和95所学校位于的区域5 - 15 V m - 1,超过15 m - 1。电压输电线路和电力变电站在德黑兰郊区及其建议在背景的影响线城市的电场很低。0.97公里2德黑兰位于城市边界相邻的高压输电线路有一个电场在5到15 V的范围米1。可用的标准。得出的结论是,公众不暴露风险背景电场在大都市德黑兰。表明,学校有更多的接受者比医院理想的状态。流行病学研究可能导致更多理解的对公共卫生的影响。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号