Modern pre-clinical radiation therapy (RT) research requires high precision and accurate dosimetry to facilitate the translation of research findings into clinical practice. Several systems are available that provide precise delivery and on-board imaging capabilities, highlighting the need for a quality management program (QMP) to ensure consistent and accurate radiation dose delivery. An ongoing, simple, and efficient QMP for image-guided robotic small animal irradiators used in pre-clinical RT research is described. Protocols were developed and implemented to assess the dose output constancy (based on the AAPM TG-61 protocol), cone-beam computed tomography (CBCT) image quality and object representation accuracy (using a custom-designed imaging phantom), CBCT-guided target localization accuracy and consistency of the CBCT-based dose calculation. To facilitate an efficient read-out and limit the user dependence of the QMP data analysis, a semi-automatic image analysis and data representation program was developed using the technical computing software MATLAB. The results of the first 6-mo experience using the suggested QMP for a Small Animal Radiation Research Platform (SARRP) are presented, with data collected on a bi-monthly basis. The dosimetric output constancy was established to be within +/- 1 %, the consistency of the image resolution was within +/- 0.2 mm, the accuracy of CBCT-guided target localization was within +/- 0.5 mm, and dose calculation consistency was within +/- 2 s (+/- 3%) per treatment beam. Based on these results, this simple quality assurance program allows for the detection of inconsistencies in dosimetric or imaging parameters that are beyond the acceptable variability for a reliable and accurate pre-clinical RT system, on a monthly or bi-monthly basis.
机译:现代临床前放疗(RT)研究要求精度高、准确剂量测定法,以促进翻译的研究结果为临床实践。系统可提供精确交付和车载成像功能,强调质量管理的需要程序(QMP),以确保一致和准确辐射剂量交付。图像引导机器人的有效QMP小在临床前动物辐照器使用RT研究描述。和实施评估剂量输出恒常性(基于AAPM tg - 61协议),cone-beam计算机断层扫描(CBCT)的形象质量和准确性(使用对象表示一个专门设计的成像幻影),CBCT-guided目标定位的准确性和一致性CBCT-based剂量计算。高效的读出和限制用户依赖QMP数据分析的半自动图像分析和数据表示计划使用的技术开发的计算软件MATLAB。使用建议QMP小动物辐射研究平台(SARRP)提出,在双月收集的数据的基础上。在+ / - 1%,建立一致性图像的分辨率在+ / - 0.2毫米,CBCT-guided目标定位的准确性在+ / - 0.5毫米,剂量计算一致性是在+ / - 2 s (+ / - 3%)治疗光束。简单的质量保证程序允许检测剂量测定的或不一致的成像参数超出了可接受的可变性的可靠和准确的临床前RT系统,每月或双月的基础。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号