首页> 外文期刊>Health Physics: Official Journal of the Health Physics Society >Dose Reconstruction Using Electron Paramagnetic Resonance Dosimetry on Tooth Enamel From Wild Boar Living in the Fukushima Exclusion Zone
【24h】

Dose Reconstruction Using Electron Paramagnetic Resonance Dosimetry on Tooth Enamel From Wild Boar Living in the Fukushima Exclusion Zone

机译:使用电子顺剂量重建从野生共振剂量测定法对牙釉质住在福岛禁区野猪

获取原文
获取原文并翻译 | 示例
           

摘要

The goal of the study was to establish characteristics of Japanese wild boar tooth enamel in the dose region of 0.25-2.0 Gy and to reconstruct external absorbed doses to wild boar native to the Fukushima exclusion zone using electron paramagnetic resonance dosimetry. The significance of Japanese wild boar in their ecosystem and their position within the trophic hierarchy make the wild boar a species of particular importance and therefore, the focus of this study. Dose response linearity and variability of enamel originating from various wild boar were investigated. Radiation dose response of Japanese wild boar tooth enamel in the range of 0.25-2.0 Gy was found to be linear, and the average variation in dose response between teeth originating from the same boar specimen was nearly 30%. No statistically significant difference in dose response was found based on sex of the boar or in permanent molar teeth of boar of differing ages. Electron paramagnetic resonance absorbed doses to boar tooth enamel were successfully reconstructed using the calibration curve method and converted into estimates of absorbed dose to soft tissue with large associated confidence intervals. The critical level dose value for the calibration curve was 1.0 Gy and the detection limit dose was 1.8 Gy, suggesting that this method would be more beneficial for boar with lifetime absorbed doses greater than 1.0 Gy. The method of reconstructing external absorbed doses using electron paramagnetic resonance dosimetry with tooth enamel from Japanese wild boar as dosimeters has proven to be a viable method which can be used to reconstruct absorbed doses to wildlife in accident-stricken areas in the absence of alternative dosimetry.
机译:这项研究的目的是建立日本野猪的牙齿的特征搪瓷的剂量地区0.25 - -2.0 Gy,重建外部吸收剂量野猪原产于福岛禁区电子顺磁共振剂量测定法。日本野猪的意义在营养生态系统和他们的立场层次结构使野猪的一种特别重要,因此,关注的焦点本研究。可变性的搪瓷来自不同野猪。日本野猪牙釉质的响应0.25 - -2.0 Gy的范围是线性的,,平均剂量反应的变化牙齿之间来自相同的野猪标本是将近30%。在剂量反应被发现显著差异基于性别的野猪或永久的摩尔不同年龄层的野猪的牙齿。顺磁共振吸收剂量野猪牙釉质被成功重建使用校准曲线法和转换吸收剂量的估算软组织有大量相关的置信区间。临界水平剂量值校准曲线是1.0 Gy,检测极限剂量1.8 Gy,表明这个方法会更有利于野猪一生吸收剂量大于1.0 Gy。外部使用电子吸收剂量顺磁共振剂量测定法与牙齿从日本野猪牙釉质测试仪被证明是一种可行的方法,可用于重建吸收剂量的野生动物在缺乏accident-stricken区域替代剂量测定法。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号