首页> 外文期刊>Health Physics: Official Journal of the Health Physics Society >Preliminary Experiences with the Rexon UL-320-FDR: An Automated Thermoluminescent Dosimeter Reader with Removable Contact Heating Planchets and an Infrared Temperature Feedback System.
【24h】

Preliminary Experiences with the Rexon UL-320-FDR: An Automated Thermoluminescent Dosimeter Reader with Removable Contact Heating Planchets and an Infrared Temperature Feedback System.

机译:初步体验Rexon ul - 320罗斯福:自动热释光的剂量计的读者可移动接触加热造币用金属板和一个红外温度反馈系统。

获取原文
获取原文并翻译 | 示例
           

摘要

The Rexon UL-320 FDR is a novel resistive-heating thermoluminescent dosimeter reader with a unique temperature measurement system and an automated dosimeter processing mechanism. The removable contact heating planchets have black-body adhesives on the back for capturing temperature information with infrared sensors. A heating cycle feedback loop ensures accurate, precise, and reproducible heating sequences. Heating rates between 0.8 and 40°C s-1 for up to 1,000 s are possible. Photomultiplier tube sensitivity and drift, dark current counts, and planchet glow were measured experimentally. Additionally, 25 LiF:Mg,Ti dosimeters were calibrated to demonstrate reader performance. Sensitivity was optimized at 1,200 V, which produced the highest reference light count to dark current count ratio while extending photomultiplier tube life. Dark current counts measured with typical time-temperature profiles for LiF:Mg,Ti were below 10 counts per channel but increased by up to 2.5% for more extreme heating cycles. Reader sensitivity drifts of up to 10% were observed during extended automated operations with typical time-temperature profiles. Total counts resulting from planchet glow decreased with faster heating rates. Calibrations performed with LiF:Mg,Ti dosimeters yielded results comparable to more established reader designs. Spikes were observed in ~3% of the glow curves from planchet dust and oil burning off at elevated temperatures. The use of N2 gas and sensitivity drift corrections are recommended to improve dosimetry performance for the UL-320 FDR reader.
机译:Rexon ul - 320 resistive-heating罗斯福是一个小说热释光的放射量测定器独特的读者温度测量系统和自动化剂量计处理机制。接触加热圆片黑体粘合剂在捕捉温度信息与红外传感器。循环反馈回路,确保准确、精确、和可再生的供暖序列。0.8到40°C s - 1 1000年代可能的。漂移、暗电流计数和圆片发光测量实验。生活:镁、钛剂量计校准说明读者的性能。优化在1200 V,产生最高参考光数到暗电流计算比例而光电倍增管寿命更长。与典型的当前计数测量生活的时间——温度资料:镁、钛下面每通道,但增加了10项2.5%更极端的加热周期。灵敏度漂移高达10%的观察在扩展使用典型的自动化操作时间——温度资料。从造币用金属板发光下降更快的加热利率。指示剂,结果与更多建立了阅读器的设计。~ 3%的从造币用金属板灰尘和发光曲线燃油温度升高。N2气体和灵敏度漂移修正建议提高剂量学性能ul - 320年罗斯福读者。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号