首页> 外文期刊>Arthroscopy: the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association >Supplemental Fixation of Inner Graft Limbs in All-Inside, Quadrupled, Single-Tendon Anterior Cruciate Ligament Reconstruction Graft Construct Yields Improved Biomechanical Properties
【24h】

Supplemental Fixation of Inner Graft Limbs in All-Inside, Quadrupled, Single-Tendon Anterior Cruciate Ligament Reconstruction Graft Construct Yields Improved Biomechanical Properties

机译:补充固定内移植肢体所有内部,翻了两番,腱前交叉韧带重建移植构建产量提高了生物力学特性

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose: To compare the time-zero load to failure of a quadrupled, single-tendon, all-inside anterior cruciate ligament (ACL) reconstruction graft construct with (supplemented) and without the incorporation of inner-limb whipstitch sutures (control) into a tibial suspensory fixation button. Methods: Eight matched pairs of peroneus longus tendons were prepared according to a quadrupled, all-inside ACL soft-tissue graft technique with 1 side serving as a control and the contralateral side supplemented. The constructs were biomechanically tested for strain in the inner and outer limbs during a preconditioning protocol, single-cycle load to failure, and elongation of the whole construct. Results: Ultimate load to failure was significantly higher in the supplemented group: 797.5 +/- 49.6 N (95% confidence interval [CI], 763.13-831.87 N) versus 719.6 +/- 69.6 N (95% CI, 671.38-767.82 N; P = .044). Less graft elongation at failure was observed in the supplemented group (3.1 +/- 1.5 mm; 95% CI, 2.07-4.17 mm) versus the control group (21.0 +/- 21.2 mm; 95% CI, 6.31-35.69 mm; P = .052). The number of grafts undergoing a 5-mm or greater change in length at failure was 1 of 8 in the supplemented group versus 5 of 8 in the control group (P = .038). Conclusions: Inner-limb supplemental tibial fixation results in higher time-zero load to failure and decreased graft elongation in a quadrupled, single-tendon, all-inside ACL reconstruction graft construct.
机译:目的:比较时刻0加载失败翻了两番,腱,所有内部前交叉韧带(ACL)重建贪污构造(补充)和没有的inner-limb锁缝缝合线(控制)胫骨悬固定按钮。腓骨长肌肌腱是准备翻了两番,所有内部ACL软组织移植物1侧作为控制和技术侧方补充。结构是生物力学测试压力在内部和外部的四肢预处理协议,单循环负载失败,整个构造的伸长。结果:失败是极限荷载显著的高于补充组:797.5 + / - 49.6 N(95%可信区间(CI),763.13 - -831.87 N)和719.6 + / - 69.6(95%可信区间,671.38 - -767.82 N;失败是补充组中观察到(3.1 + / - 1.5毫米;对照组(21.0 + / - 21.2毫米;6.31 - -35.69毫米;经历一场5毫米或更大的长度变化失败是1 8补充组对5 8的对照组(P = .038)。结论:Inner-limb补充胫骨固定导致更高的时刻0负载失败和减少贪污伸长翻了两番,腱,内部的ACL重建移植构建。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号