首页> 外文期刊>The journal of hand surgery Asian-Pacific volume. >Use of Computed Tomography in Determining the Occurrence of Dorsal and Intra-articular Screw Penetration in Volar Locking Plate Osteosynthesis of Distal Radius Fracture
【24h】

Use of Computed Tomography in Determining the Occurrence of Dorsal and Intra-articular Screw Penetration in Volar Locking Plate Osteosynthesis of Distal Radius Fracture

机译:在确定使用的计算机断层扫描发生的背和关节内的螺丝渗透在手掌的锁定接骨板桡骨远端的骨折

获取原文
获取原文并翻译 | 示例

摘要

Background: The use of volar locking plate in distal radius fracture can lead to extensor tendon rupture due to dorsal screw penetration. The aim of our study was to investigate the occurrence of dorsal and intra-articular screw penetration using CT scan after volar distal radius osteosynthesis for distal radius fractures.Methods: Thirty patients who underwent distal volar locking plate for distal radius fracture were included in a retrospective study. In all 30 patients no dorsal and intra-articular screw penetration were detected on standard AP and lateral views of a plain radiograph. CT scan of the operated wrist was performed to determine the number of intra-articular and dorsal screw penetrations. Clinical examination was performed to determine the wrist functions in comparison to the normal wrist.Results: Nineteen wrists were noted to have screw penetration either dorsally or intraarticularly. The highest incidence is in the 2nd extensor compartment where 13 screws had penetrated with a mean of 2.46 mm. Six screws penetrated into the distal radial ulnar joint and five screws into the wrist joint with a mean of 2.83 mm and 2.6 mm, respectively. However, there was no incidence of tendon irritation or rupture.Conclusions: This study demonstrated a high incidence of dorsal and intra-articular screw penetration detected by CT scan which was not apparent in plain radiograph. We recommend that surgeons adhere to the principle of only near cortex fixation and downsizing the locking screw length by 2 mm.
机译:背景:足底的锁定板的使用远端骨折半径会导致伸肌由于背螺钉穿透腱断裂。我们的研究的目的是调查发生的背和关节内的螺丝渗透在手掌的远端后使用CT扫描桡骨远端骨缝术为半径骨折。对远端远端掌侧锁定板半径骨折进行回顾性研究。在所有30个病人没有背,关节内的螺钉穿透检测标准和侧面视图的一个普通的x光照片。确定执行操作的手腕关节内的和背侧螺钉的数量缝隙。确定手腕功能相比正常的手腕。指出螺钉穿透要么背或intraarticularly。第二伸肌间隔,13个螺丝渗透平均值为2.46毫米。渗透到远端桡尺骨关节5个螺丝到腕关节的意思分别为2.83毫米和2.6毫米。没有肌腱发炎的几率还是破裂。的背和关节内的高发病率螺钉穿透由CT扫描检测到在普通x光照片不明显。外科医生只坚持的原则靠近皮层固定和裁员的锁定螺丝长度×2毫米。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号