...
首页> 外文期刊>Biosensors & Bioelectronics: The International Journal for the Professional Involved with Research, Technology and Applications of Biosensers and Related Devices >Chemiluminescence flow biosensor for glucose based on gold nano particle-enhanced activities of glucose oxidase and horseradish peroxidase
【24h】

Chemiluminescence flow biosensor for glucose based on gold nano particle-enhanced activities of glucose oxidase and horseradish peroxidase

机译:化学发光流对葡萄糖生物传感器的基础黄金纳米particle-enhanced活动葡萄糖氧化酶和辣根过氧化物酶

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

In this work, a novel chemiluminescence (CL) flow biosensor for glucose was proposed. Glucose oxidase (GOD), horseradish peroxidase (HRP) and gold nanoparticles were immobilized with sol-gel method on the inside surface of the CL flow cell. The CL detection involved enzymatic oxidation of glucose to D-gluconic acid and H2O2, and then the generated H2O2 oxidizing luminol to produce CL emission in the presence of HRP. It was found that gold nanoparticles could remarkably enhance the CL respond of the glucose biosensor. The enhanced effect was closely related to the sizes of gold colloids, and the smaller the size of gold colloids had the higher CL respond. The immobilization condition and the CL condition were studied in detail. The CL emission intensity was linear with glucose concentration in the range of 1.0 x 10(-5) mol L-1 to 1.0 x 10(-3) mol L-1, and the detection limit was 5 x 10(-6) mol L-1 (3 sigma). The apparent Michaelis-Menten constant of GOD in gold nano particles/sol-gel matrix was evaluated to be 0.3 mmol L-1, which was smaller than that of GOD immobilized in sol-gel matrix without gold nanoparticles. The proposed biosensor exhibited short response time, easy operation, low cost and simple assembly, and the proposed biosensor was successfully applied to the determination of glucose in human serum. (C) 2008 Elsevier B.V. All rights reserved.
机译:在这项工作中,新颖的化学发光(CL)流提出了对葡萄糖生物传感器。氧化酶(上帝),辣根过氧化物酶(合)和金纳米粒子与溶胶-凝胶固定化方法细胞CL流的内表面。CL检测酶的氧化葡萄糖D-gluconic酸和过氧化氢,然后生成过氧化氢生产氯氧化鲁米诺排放在合。金纳米粒子可以显著提高CL反应的葡萄糖生物传感器。增强了尺寸效应密切相关金胶体,较小的大小金胶体有更高的CL回应。固定条件和CL条件详细研究了。与葡萄糖浓度线性吗1.0 x 10(5)摩尔l - 1到1.0 x 10(3)摩尔l - 1,检出限5 x 10(6)摩尔l - 1(3σ)。恒神的黄金纳米粒子/溶胶-凝胶法矩阵是评估0.3更易与l - 1,小于,神的固定化在吗没有金纳米粒子溶胶-凝胶法矩阵。提出了生物传感器表现出短的响应时间,操作简单、低成本和简单的组装和该生物传感器已成功应用在人类血清葡萄糖的测定。(C) 2008爱思唯尔帐面价值保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号