Biomechanical properties of materials used in static facial suspension.

机译:生物力学属性中使用的材料静态面部悬挂。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

OBJECTIVE: To compare the biomechanical properties of the superficial (human acellular dermis); (AlloDerm; LefeCell Corp, Branchburg, NJ) and deep layers of cadaveric dermis and expanded polytetrafluoroethylene (ePTFE); (Gore-Tex; W. L. Gore & Associates, Flagstaff, Ariz). METHODS: Sixteen samples of superficial dermis (AlloDerm), 12 samples of deep dermis, and 12 samples of ePTFE were axial loaded on a materials testing machine. Maximum load to failure and stiffness were calculated and statistical analysis was performed to compare the materials. RESULTS: Dermis samples had statistically greater mean stiffness compared with ePTFE samples. There was no statistical difference of maximum load to failure comparing ePTFE with superficial dermis. There was a statistical difference in maximum load to failure between ePTFE and deep dermis. There was no statistical difference between the superficial and deep layers of the dermis with respect to stiffness or maximum load to failure. CONCLUSIONS: Cadaveric dermishas some biomechanical properties to be a superior material for static facial suspension. There was larger than expected variability in both parameters (stiffness and maximum load to failure) tested in dermis samples, which may correlate with occasional clinical failure.
机译:目的:比较生物力学属性肤浅的(人类非细胞真皮);(AlloDerm;尸体的深层,真皮和扩展聚四氟乙烯(ePTFE);戈尔& Associates,亚利桑那州的弗拉格斯塔夫)。16个样品表面的真皮(AlloDerm),12的深真皮样品,12个样品ePTFE轴向加载在材料测试机器。计算和统计分析进行比较的材料。真皮样品有统计上大的意思刚度与ePTFE样本。无统计差异最大负载失败比较ePTFE和肤浅的真皮。有一个统计的差异最大加载失败ePTFE与真皮深处。没有统计学差异真皮的表面和深度层对刚度或最大加载失败。结论:尸体dermishas一些生物力学性能优越材料静态面部悬挂。在这两方面都比预期的变化参数(刚度和最大负载在真皮样品测试失败),这可能偶尔与临床失败。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号