...
首页> 外文期刊>Clinical and vaccine immunology: CVI >Evaluation of the Bio-Rad BioPlex 2200 syphilis multiplex flow immunoassay for the detection of IgM- and IgG-class antitreponemal antibodies.
【24h】

Evaluation of the Bio-Rad BioPlex 2200 syphilis multiplex flow immunoassay for the detection of IgM- and IgG-class antitreponemal antibodies.

机译:2200年评估Bio-Rad BioPlex梅毒多路复用流检测的免疫测定IgM——IgG-class antitreponemal抗体。

获取原文
获取原文并翻译 | 示例
           

摘要

The laboratory diagnosis of syphilis is based primarily upon serologic findings. Historically, serologic testing for syphilis has relied on assays such as rapid plasma reagin, fluorescent treponemal antibody absorption, Treponema pallidum particle agglutination (TP-PA), and more recently, enzyme immunoassay (EIA). In this study, we evaluated the performance of a novel multiplex flow immunoassay (BioPlex 2200 Syphilis; Bio-Rad Laboratories, Hercules, CA) for the detection of antitreponemal IgG- and IgM-class antibodies. Serum specimens (n = 1,008) submitted for routine treponema-specific antibody testing by syphilis IgM and IgG EIA (Trep-Chek; Phoenix-Biotech, Mississauga, Ontario, Canada) were also analyzed by the BioPlex Syphilis multiplex assay. Specimens showing discordant results were repeat tested, with further discrepancies being arbitrated by TP-PA. Compared directly to the results of EIA, the BioPlex IgG assay demonstrated 98.7% (77/78) sensitivity and 99.4% (916/930) specificity. Compared to the Trep-Chek IgM EIA, the BioPlex IgM assay showed 80% (4/5) sensitivity and 97.9% (652/666) specificity. These results indicate that the BioPlex Syphilis multiplex assay shows similar serological agreement with EIA while allowing for a fully automated random-access platform that provides faster (1.7 h for 100 samples versus 4.5 h by EIA) and higher-throughput (800 samples per 9 h versus 200 samples by EIA) analysis of the syphilis serologic response.
机译:梅毒实验室诊断的基础主要在血清学的发现。对梅毒血清学检查依赖化验,如快速血浆反应素荧光梅毒螺旋体抗体吸收螺旋体颗粒凝集(TP-PA)等等最近,酶免疫测定(EIA)。研究中,我们评估了一种新型的性能多路复用流免疫测定(BioPlex 2200梅毒;检测antitreponemal免疫球蛋白,IgM-class抗体。提交常规treponema-specific抗体测试梅毒IgM和免疫球蛋白环评(Trep-Chek;Phoenix-Biotech,加拿大安大略省米西索加)也分析了BioPlex梅毒吗多元分析。结果重复测试,进一步差异被TP-PA仲裁。直接环境影响评价结果,BioPlex免疫球蛋白试验证明了98.7%(77/78)的敏感性99.4%(916/930)的特异性。Trep-Chek IgM环评,BioPlex IgM化验显示灵敏度80%(4/5)和97.9% (652/666)特异性。BioPlex梅毒多元分析表明相似与环评血清学协议同时允许一个完全自动化的随机访问平台提供更快(1.7 h 100样品和4.5由环评h)和更高的吞吐量(800样本/9 h和200个样本EIA)的分析梅毒血清学的反应。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号