Abstract Incineration experiment of medical waste was carried out in a mobile animal carcass incinerator. Simulated medical waste (69% cotton, 1.5% wood product, 4.5% mask and 25% moisture) was used as raw material. The temperature trend of first and second combustion chamber, the operating conditions and the emission characteristics of gaseous pollutants were studied. The results indicated that the temperature of first combustion chamber can be maintained at 550–650?°C without external heating, while in the final stage a burner was used to realize the burnout of material. The temperature of the second combustion chamber was always lower than that of the first combustion after the burner stopped working. The concentration of CO emission in flue gas was high due to the low disposal efficiency of the mobile incinerator, while NOX and SO2 emission concentrations were far below the standard limit value (GB 18484-2001).
机译:在移动动物尸体焚化炉中进行了抽象焚化实验。 模拟的医疗废物(69%的棉花,1.5%的木材产品,4.5%的面膜和25%的水分)用作原料。 研究了第一和第二燃烧室的温度趋势,气态污染物的工作条件和发射特性。 结果表明,第一燃烧室的温度可以保持在550–650?°C的情况下,而无需外部加热,而在最后阶段,使用燃烧器来实现材料的倦怠。 燃烧器停止工作后,第二燃烧室的温度总是低于第一燃烧的温度。 由于移动焚化器的处置效率较低,而NOX和SO2排放浓度远低于标准极限值(GB 18484-2001),因此烟气中的CO排放浓度很高。