We present a conceptual sampling electromagnetic calorimeter based on secondary electron emission process. The secondary electron emission processwas implemented in Geant4 as a user physics class, which accurately reproduces the energy spectrumand yield of secondary electrons for thin metals. The simulation results for the response linearity and energy resolution are compared with that of a scintillation calorimeter. The response and energy resolution of the calorimeter were obtained for electron energies up to 50 GeV. The response linearity to electromagnetic showers is to within 1.5%, whereas the energy resolution is σ/E = (44%) GeV~(1/2)/√E for 2.5 cm sampling of iron absorber.
机译:我们提出了基于二级电子发射过程的概念采样电磁热量表。 Geant4中实施的二级电子发射过程是用户物理类,该类别准确地重现了薄金属的二级电子的能量谱和次级产量。 将响应线性和能量分辨率的仿真结果与闪烁量热计的仿真结果进行了比较。 获得高达50 GEV的电子能量的量热计的响应和能量分辨率。 电磁淋浴的响应线性性在1.5%以内,而能量分辨率为σ/e =(44%)GEV〜(1/2)/√E,用于2.5 cm铁吸收器采样。