Abstract Nuclear imaging is used in the evaluation of painful arthroplasties for diagnosing loosening or periprosthetic joint infection (PJI). The purpose of this systematic review is to depict the reproducibility of the various nuclear imaging modalities used in the assessment of painful hip and knee arthroplasties. A systematic review of the literature was conducted with a comprehensive search of MED LINE to identify clinical studies investigating the intra-and inter-observer agreement of nuclear imaging modalities in diagnosing PJI and mechanical loosening. A total of 3.000 studies, published between 2004 and 2020, were reviewed and 16 studies met the inclusion criteria. Quality assessment identified concerns with regard to the internal validity in approximately 40% of the included studies. A meta-analysis could not be performed because of insufficient available clinical data. The intra-observer agreement was poorly investigated. The included studies reported an inter-observer agreement of "slight" to "excellent" for bone scintigraphy, "moderate" to "substantial" for leukocyte scintigraphy, "substantial" to "almost perfect" for combined leukocyte and bone marrow scintigraphy, and "fair" to "substantial" for anti-granulocyte scintigraphy. Hybrid imaging with SPECT/CT and FDG-PET/CT demonstrated "substantial" and "almost perfect" inter-observer agreement for symptomatic hip prostheses, respectively. The reproducibility of nuclear imaging is underreported in clinical studies investigating painful knee and hip arthroplasties. Moreover, the included studies demonstrated methodological concerns with a high risk of bias. The available evidence demonstrated a wide range of inter-observer agreement using scintigraphy. Hybrid imaging with SPECT/CT and FDG-PET/CT may improve the accuracy of interpretation and reproducibility. However, literature provides limited data to support this assumption.
机译:抽象的核成像用于评估疼痛关节塑料的评估,以诊断松动或人假体关节感染(PJI)。这项系统评价的目的是描述用于评估疼痛髋关节和膝关节塑料的各种核成像方式的可重复性。对文献进行了系统的综述,对MED系列进行了全面的搜索,以识别研究核成像方式在诊断PJI和机械松弛方面的观察者间和观察者间一致性。在2004年至2020年之间发表的总共3.000项研究进行了审查,16项研究符合纳入标准。质量评估确定了大约40%纳入研究的内部有效性的关注。由于可用的临床数据不足,因此无法进行荟萃分析。对观察者的协议的研究很少。纳入的研究报道了对骨闪烁显像的“轻微”与“极好”的观察者一致性,对于白细胞闪烁显像,“中等”至“实质”,“实质性”,对于白细胞和骨髓刺激性组合,“几乎是完美的”,以及“几乎是完美的”。公平的抗植物细胞闪烁显像。与SPECT/CT和FDG-PET/CT进行的混合成像分别显示出“实质性”和“几乎完美”的症状性髋关节假体一致性。核成像的可重复性在研究疼痛膝关节和髋关节塑料的临床研究中不足。此外,纳入的研究表明了具有高偏见风险的方法论问题。现有证据表明,使用闪烁显像是广泛的观察者一致性。使用SPECT/CT和FDG-PET/CT进行混合成像可以提高解释和可重复性的准确性。但是,文献提供了有限的数据来支持这一假设。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号