A Simple and High-Accuracy PID-Based Temperature Control System for Magnetic Hyperthermia Using Fiber Optic Thermometer

机译:使用光纤温度计,一种简单且高准确的基于PID的温度控制系统,用于磁性高温

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Magnetic hyperthermia is very promising cancer therapy in which heating temperature is expected to be a key determinant for its success. Herein, we present a simple, real-time, and high-accuracy proportional-integral-derivative-based temperature control system for magnetic hyperthermia using widely-used induction heater and fiber optic thermometer. Our in vitro result shows that the temperature of clinically-approved Resovist (R) (0.5 ml) was accurately controlled with very small overshoot (e.g., 45.0 +/- 0.07 degrees C and 55.0 +/- 0.11 degrees C for low- and high-temperature magnetic hyperthermia). Our system has the potential to be used for magnetic hyperthermia either alone or together with other cancer treatment modalities for basic and clinical studies. (c) 2021 Institute of Electrical Engineers of Japan. Published by Wiley Periodicals LLC.
机译:磁性高温是非常有前途的癌症治疗,预计加热温度是其成功的关键决定因素。 本文中,我们使用广泛使用的感应加热器和光纤温度计提出了一个简单,实时和高临界性比例成比例的温度控制系统,用于磁性高温。 我们的体外结果表明,临床批准的储备师(R)(0.5 mL)的温度通过非常小的过冲(例如45.0 +/- 0.07摄氏度C和55.0 +/- 0.11摄氏度,可用于低位和高高的55.07度+/- 0.07摄氏度(例如45.0 +/- 0.07度)C。 - 温度磁性高温)。 我们的系统有可能单独或与其他癌症治疗方式一起用于基础研究和临床研究。 (c)2021日本电气工程师研究所。 由Wiley Wendericals LLC出版。