To optimize the plate-fin heat exchangers in the cryogenic processing system, the heat transfer characteristics of two-phase flow boiling for high-efficiency and pressure-resistant offset strip fins in plate-fin heat exchangers were investigated experimentally. The experimental conditions cover heat fluxes of 0.7-5.5 kW/m(2), mass fluxes of 64-128 kg/(m(2).s) and vapor qualities of 0.1-1.0. The research results show that, as the vapor quality increases, the heat transfer coefficient initially increases and then decreases, representing a maximum at vapor quality of 0.75-0.85; the critical conditions of the bubbly-annular transformation and the annular-mist transformation are corresponding to the void fractions of 0.92 and 0.985, respectively. A new correlation of two-phase heat transfer coefficient for flow boiling in offset strip fin channels was developed based on the experimental data in the present study and in the literature, and the prediction deviation is within +/- 25%.
机译:为了优化低温处理系统中的板翅式换热器,实验研究了板翅式换热器中高效耐压偏置翅片的两相流沸腾传热特性。实验条件包括热通量为0.7-5.5kw/m2,质量通量为64-128kg/(m2)。s) 蒸汽质量为0.1-1.0。研究结果表明,随着蒸汽质量的增加,传热系数先增大后减小,在蒸汽质量为0.75-0.85时达到最大值;泡状环转变和环雾转变的临界条件分别对应于0.92和0.985的空隙率。根据本研究和文献中的实验数据,建立了一种新的偏置带肋通道内流动沸腾的两相传热系数关联式,预测误差在+/-25%以内。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号