Biomechanical Assessment of Restored Mandibular Molar by Endocrown in Comparison to a Glass Fiber Post‐Retained Conventional Crown: 3D Finite Element Analysis

机译:玻璃纤维后常规冠的玻璃纤维和玻璃纤维恢复颌骨摩尔的生物力学评价:3D有限元分析

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Abstract Purpose To compare equivalent and contact stresses in a mandibular molar restored by all‐ceramic crowns through two methods: ceramic endocrowns and ceramic crowns supported by fiber‐reinforced composite (FRC) posts and core, by using 3D finite element analysis during normal masticatory load. Materials and Methods Three 3D models of a mandibular first molar were made and labeled as such: intact molar with no restoration (A); ceramic endocrown‐restored molar (B); ceramic crown supported by FRC posts and core restored molar (C). By using 3D FE analysis with contact components, normal masticatory load was simulated. The mvM stresses in all models were calculated. Maximal mvM stresses in the ceramic of restorations, dentin, and luting cement were contrasted among models and to values of materials' strength. Contact shear and tensile stresses in the restoration/tooth interface around restorations were also calculated. Results The highest mvM stress levels in the enamel and dentin for the tooth restored by ceramic endocrown were lower in the crown ceramic than in tooth restored with FRC posts and all‐ceramic crowns; however, in the resin adhesive cement interface it was lower for ceramic crown supported by FRC posts than the in ceramic endocrown restoration. The maximum contact shear and tensile stress values along the restoration/tooth interface of ceramic endocrowns were lower than those with ceramic crowns supported by FRC posts. Conclusions Ceramic endocrown restorations presented a lower mvM stress level in dentin than the conventional ceramic crowns supported by FRC posts and core. Ceramic endocrown restorations in molars are less susceptible to damage than those with conventional ceramic crowns retained by FRC posts. Ceramic endocrowns properly cemented in molars must not be fractured or loosen during normal masticatory load. Therefore, ceramic endocrowns are advised as practicable, minimally invasive, and esthetic restorations for root canal treated mandibular molars.
机译:摘要目的通过正常咀嚼负荷下的三维有限元分析,比较全瓷冠修复下颌磨牙的等效应力和接触应力。材料与方法制作下颌第一磨牙三维模型,并标记为:未修复的完整磨牙(a);陶瓷内生磨牙(B);由FRC桩和核修复磨牙(C)支撑的烤瓷冠。通过接触部件的三维有限元分析,模拟正常咀嚼负荷。计算了所有模型的mvM应力。将修复体、牙本质和粘接剂陶瓷中的最大mvM应力与不同模型和材料强度值进行对比。还计算了修复体周围修复体/牙齿界面的接触剪应力和拉应力。结果与FRC桩和全瓷冠修复的牙釉质和牙本质相比,烤瓷冠修复的牙釉质和牙本质的最大mvM应力水平较低;然而,在树脂-粘接剂-水泥界面中,FRC桩支撑的烤瓷冠比内生烤瓷修复体低。陶瓷内生牙冠修复体/牙界面的最大接触剪应力和拉应力值均低于FRC桩支持的烤瓷冠修复体/牙界面的最大接触剪应力和拉应力值。结论与FRC桩核支持的传统烤瓷冠相比,内生陶瓷修复体在牙本质中的mvM应力水平较低。磨牙内生陶瓷修复体比FRC桩保留传统陶瓷冠的修复体更不易受损。在正常咀嚼负荷期间,磨牙中正确粘合的陶瓷内牙槽骨不得断裂或松动。因此,对于根管治疗的下颌磨牙,建议尽可能使用陶瓷内生牙轮,进行微创和美观的修复。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号