Many variables can influence the results of gastric emptying scintigraphy (GES). A lack of methodologic standardization may cause variability, limit comparisons, and decrease the credibility of the test. To address this, in 2009, the Society of Nuclear Medicine and Molecular Imaging (SNMMI) published a procedure guideline describing a standardized, validated GES protocol for adults. Laboratories must closely follow the consensus protocol to provide valid and standardized results and improve patient care. The Intersocietal Accreditation Commission (IAC) evaluates compliance with guidelines as part of the accreditation process. The rate of compliance with the GES guideline at a national level has not been assessed. The aim of this study was to quantify compliance with the standardized protocol in a large cohort of laboratories from different institutions and practice settings across the United States. Methods: The IAC Nuclear/PET database was used to extract GES protocols from all laboratories applying for accreditation from 2013 to 2015. Each protocol was assessed for compliance with the methods described in the SNMMI GES procedure guidelines. Fourteen binary variables were assessed: patient preparation (4 variables), meal content (5 variables), acquisition (2 variables), and processing (3 variables). Results: Protocols from 127 labs demonstrated that patient preparation was the category with which the laboratories were least compliant. Instructions for blood glucose monitoring and withholding of medications were problematic. Overall, 69.3% of protocols were not compliant with the content or preparation of the consensus meal: 47.3% used whole eggs instead of egg whites, and additional ingredients not recommended in the guidelines were also frequently used. Only 3.1% of laboratories were fully compliant with all 14 variables. Over half the laboratories were compliant with only 5 variables or less. Conclusion: Almost 8 y after the publication of the SNMMI GES guidelines, there is low protocol adherence among laboratories applying for IAC Nuclear/PET accreditation. This substantial degree of guideline noncompliance is concerning. The variability in GES protocols may have a significant effect on patient management, as results may be inaccurate. Consistent use of the standardized GES protocol permits interpretation of results in a standardized manner that allows interlaboratory comparisons and fosters acceptance of the test validity by referring clinicians.
机译:许多变量会影响胃排空闪烁扫描(GES)的结果。缺乏方法标准化可能会导致变异,限制比较,并降低测试的可信度。为了解决这个问题,2009年,核医学和分子成像学会(SNMMI)发布了一份程序指南,描述了一个标准化、经验证的成人GES方案。实验室必须严格遵守共识协议,以提供有效和标准化的结果,并改善患者护理。作为认证过程的一部分,社会间认证委员会(IAC)对指南的合规性进行评估。尚未评估国家层面上符合GES指南的比率。本研究的目的是量化来自美国不同机构和实践环境的大量实验室对标准化方案的遵守情况。方法:使用IAC Nuclear/PET数据库从2013年至2015年申请认证的所有实验室提取GES协议。评估每个方案是否符合SNMMI GES程序指南中描述的方法。评估了14个二元变量:患者准备(4个变量)、膳食内容(5个变量)、获取(2个变量)和处理(3个变量)。结果:来自127个实验室的协议表明,患者准备是实验室最不符合的类别。关于血糖监测和停药的说明存在问题。总的来说,69.3%的方案不符合共识餐的内容或制备:47.3%使用全蛋代替蛋白,指南中未推荐的其他成分也经常使用。只有3.1%的实验室完全符合所有14个变量。超过一半的实验室仅符合5个或更少的变量。结论:SNMMI GES指南发布近8年后,申请IAC核/PET认证的实验室遵守协议的程度较低。这种严重的不遵守指南的情况令人担忧。GES方案的可变性可能会对患者管理产生重大影响,因为结果可能不准确。标准化GES协议的一致使用允许以标准化的方式解释结果,允许实验室间比较,并促进转诊医生对测试有效性的接受。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号