...
【24h】

Microtensile bond strengths of short surface-coated intraradicular posts

机译:短表面涂层内柱的微调粘合强度

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Actual endodontic and reconstructive concepts require posts. In this trail short posts with a coronal retentive head received tribochemical-surface coating (Tbc). The microtensile-bond-strengths (mu TBS) of the new short posts with and without additional coating were compared with the conventional posts concerning post and luting material. Root canals of 120 freshly extracted human anterior-teeth were endodontically treated to ISO size 80/length 6 mm and randomly divided into 3 groups (n = 40): Root canals of each group were prepared using respective drills of the post-system for the conventional posts (I), the new short posts without coating ((II), prototyp) and with coating (III). Posts of two materials (titanium and FRC) were inserted using two composites (RelyX-Unicem (RX), DentinBuild-Evo (DB)). After Thermocycling (5 degrees/55 degrees C, 5000x) push-out-testing was performed for the coronal (CR), medium (MR) and apical (AR) region-of-the-post. Statistical analysis was performed (ANOVA, Bonferroni correction, alpha = 0.05). Highest values of mu TBS were found for the short, coated posts (III) luted with DB at the (CR) (FRC:11.8 +/- 7.5 N/mmc, Ti:13.7 +/- 7.9N/mmc). Yet, conventional posts without coating (I) ranged on the same level at (CR) (FRC/DB:10.8 +/- 3.1N/mmc, Ti/DB:8.7 +/- 5.1N/mmc). mu TBS decreased not significantly apically within all groups. mu TBS of (II) were lower compared to (I) + (III) (p > 0.05). Posts luted with RX showed similar mu TBS regardless of the area of the post-type as well as the post-material (p > 0.05). Yet, overall post types as well as post segments turned out to be significant factors (p < 0.05, 4-way ANOVA). Short, coated posts of Ti as well as FRC revealed at least similar mu TBS to those of the conventional posts luted with both investigated composites cements.
机译:实际的牙髓治疗和重建概念需要张贴。在这项试验中,带有冠状固位头的短桩接受了摩擦化学表面涂层(Tbc)。比较了新型短桩(含和不含附加涂层)与传统桩(含桩和粘接材料)的微拉伸粘结强度(mu-TBS)。对120颗新鲜拔除的人前牙的根管进行牙髓治疗,使其达到ISO尺寸80/长度6mm,并随机分为3组(n=40):每组的根管分别使用常规桩(I)、无涂层的新短桩(II)、原型桩(III)和涂层桩(III)的桩系统钻制备。使用两种复合材料(RelyX Unicem(RX)、DentinBuild Evo(DB))插入两种材料(钛和FRC)的桩柱。在热循环(5°C/55°C,5000x)后,对桩的冠状(CR)、中(MR)和顶端(AR)区域进行推出测试。进行统计分析(ANOVA,Bonferroni校正,α=0.05)。在(CR)(FRC:11.8+/-7.5 N/mmc,Ti:13.7+/-7.9 N/mmc)下用DB稀释的短涂层桩(III)的mu-TBS值最高。然而,没有涂层(I)的传统桩在(CR)时处于相同水平(FRC/DB:10.8+/-3.1N/mmc,Ti/DB:8.7+/-5.1N/mmc)。在所有组中,mu-TBS在顶部没有显著降低。与(I)+(III)相比,(II)的mu-TBS较低(p>0.05)。用RX稀释的贴片显示出类似的mu-TBS,无论贴片类型和贴片材料的面积如何(p>0.05)。然而,总体帖子类型和帖子片段是显著因素(p<0.05,四因素方差分析)。钛和FRC的短涂层桩显示出至少与使用两种研究复合材料水泥的传统桩相似的mu-TBS。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号