首页> 外文期刊>The Journal of Prosthetic Dentistry >Influence of repeated firings on marginal, axial, axio-occlusal, and occlusal fit of metal-ceramic restorations fabricated with different techniques
【24h】

Influence of repeated firings on marginal, axial, axio-occlusal, and occlusal fit of metal-ceramic restorations fabricated with different techniques

机译:用不同技术制造的反复灌注对边缘,轴向,轴突咬合和咬合物的影响

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Statement of problemIll-fitting restorations can jeopardize dental, periodontal, and systemic health. Repeated ceramic firing may influence the fitting accuracy of restorations, but scientific information regarding this issue is lacking. PurposeThe purpose of this in?vitro study was to assess and compare the influence of repeated firings on the marginal, axial, axio-occlusal, and occlusal fit of metal-ceramic 3-unit fixed partial dentures (FPDs) manufactured with different framework methods, including casting, fully sintered hard alloy milling (FHAM), presintered soft alloy milling (PSAM), and selective laser sintering (SLS). Material and methodsA total of 60 Co-Cr metal frameworks for 3-unit FPDs were fabricated with 3 different computer-aided design and computer-aided manufacturing (CAD-CAM) techniques and conventional casting for a typodont model. The discrepancy values for premolar and molar abutments were measured by using the silicone replica technique after fabrication of the framework, second firing, fourth firing, and seventh firing. The replicas were separated into mesiodistal and buccolingual cross-sections, and digital images of the cross-sections were obtained with a stereomicroscope at?×80 magnification. The measurement points were examined to record the discrepancy values (μm) with in-built measuring software. The recorded data were subjected to repeated-measures 4-way ANOVA and the Bonferroni post hoc test (α=.05). ResultsFor all measurement periods, the marginal, axial, axio-occlusal, and occlusal discrepancy values differed significantly among the manufacturing groups (P .05). The PSAM group revealed the lowest discrepancy values at all measurement periods (P<.05), except after the second firing in the marginal and axial locations. ConclusionsThe PSAM-fabricated restorations demonstrated superior fitting accuracy. All manufacturing groups were influenced by repeated firings, except the cast group. The marginal discrepancy values of all manufacturing groups were within the range of clinical acceptability (<120 μm).
机译:问题陈述不合适的修复可能会危害牙齿、牙周和系统健康。反复烧制陶瓷可能会影响修复体的拟合精度,但缺乏有关这一问题的科学信息。目的这件事的目的是什么?体外研究旨在评估和比较重复点火对金属-陶瓷三单元固定部分义齿(FPD)边缘、轴向、轴向咬合和咬合配合的影响,该义齿采用不同的支架方法制造,包括铸造、全烧结硬质合金铣削(FHAM)、预烧结软合金铣削(PSAM)和选择性激光烧结(SLS)。材料与方法采用三种不同的计算机辅助设计和计算机辅助制造(CAD-CAM)技术,并采用传统铸造方法,制作了60个用于三单元平板显示器的钴铬金属框架。在制作框架、第二次烧制、第四次烧制和第七次烧制后,使用硅胶复制技术测量前磨牙和磨牙基牙的差异值。将复制品分为近中矢状肌和颊舌肌横截面,并在?处用立体显微镜获得横截面的数字图像?放大80倍。使用内置测量软件检查测量点,以记录差异值(μm)。对记录的数据进行重复测量4因素方差分析和Bonferroni事后检验(α=0.05)。结果在所有测量期间,制造组之间的边缘、轴向、轴向咬合和咬合差异值存在显著差异(P.05)。PSAM组在所有测量期间的差异值最低(P<0.05),边缘和轴向位置第二次点火后除外。结论PSAM制作的修复体具有较高的拟合精度。除cast组外,所有制造组均受到反复解雇的影响。所有制造组的边际差异值均在临床可接受范围内(<120μm)。

著录项

  • 来源
  • 作者单位

    Research Assistant and Dentist Department of Prosthodontics Faculty of Dentistry Near East;

    Department of Prosthodontics Faculty of Dentistry Near East University;

    Department of Prosthodontics Faculty of Dentistry Eski?ehir Osmangazi University;