X-ray computed tomography is by far the largest contributor to the radiation burden of patients. Therefore, good clinical practice in medical X-ray imaging requires the quantification of radiation exposure to optimize the image quality in relation to the absorbed dose ratio. This article covers the dosimetry part but not the quantification of image quality. Dose measurements in X-ray imaging are fundamental for two purposes: First, to set and check standards of good practice and second, to assist in assessing detriment or harm. Different application specific dose quantities are defined for general radiography and fluoroscopy, mammography and computed tomography. These provide the basis for quality assurance in X-ray imaging - for example, for acceptance testing, or for application-specific diagnostic reference levels. Non-invasive X-ray multimeters are used for quality control measurements in the beams of diagnostic X-ray devices. The patient dose is usually evaluated as the absorbed dose in organs and tissues from which the risk-related quantity "effective dose" is estimated. The latter quantity allows an estimate of the patient's risk to suffer from stochastic radiation effects. The effective dose is estimated from the measured applicationspecific dose quantities by use of dose conversion coefficients. These cannot be measured directly. Instead, they are calculated by means of Monte- Carlo simulations using computational reference models of the human body. Alternatively, they can be determined by dose measurements in adequate physical (anthropomorphic) phantoms. Simulations and dose measurements are important requirements for the development of personalized dosimetry in computed tomography.
机译:到目前为止,X射线计算机断层扫描是造成患者辐射负担的最大因素。因此,医学X射线成像的良好临床实践要求对辐射照射进行量化,以优化与吸收剂量比相关的图像质量。本文涉及剂量测定部分,但不涉及图像质量的量化。X射线成像中的剂量测量有两个基本目的:第一,设定和检查良好实践标准,第二,协助评估损害或伤害。对于普通放射照相术和荧光透视术、乳房X光摄影术和计算机断层扫描术,定义了不同的应用特定剂量。这些为X射线成像的质量保证提供了基础。无创X射线万用表用于诊断X射线设备光束的质量控制测量。患者剂量通常被评估为器官和组织中的吸收剂量,从中估计风险相关量“有效剂量”。后者可以估计患者遭受随机辐射影响的风险。通过使用剂量转换系数,根据测量的特定应用剂量量估算有效剂量。这些无法直接测量。相反,它们是通过使用人体计算参考模型的蒙特卡罗模拟来计算的。或者,它们可以通过在适当的物理(拟人)模型中进行剂量测量来确定。模拟和剂量测量是发展计算机断层扫描个性化剂量测量的重要要求。

著录项

  • 来源
    《PTB Mitteilungen》 |2020年第2期|共10页
  • 作者

    Ludwig Buermann;

  • 作者单位

    Department "Dosimetry for Radiation Therapy and Diagnostic Radiology";

  • 收录信息
  • 原文格式 PDF
  • 正文语种 ger
  • 中图分类 计量学;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号