...
首页> 外文期刊>Gastrointestinal Endoscopy >Hydrogen leak test is minimally invasive and highly specific for assessment of the integrity of the luminal closure after natural orifice transluminal endoscopic surgery procedures (with video)
【24h】

Hydrogen leak test is minimally invasive and highly specific for assessment of the integrity of the luminal closure after natural orifice transluminal endoscopic surgery procedures (with video)

机译:氢气泄漏试验是微创的侵入性,高度特异性,用于评估天然孔口分流内窥镜外科手术程序(带视频)后腔闭合的完整性

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Background: Leak-resistant closure of transluminai access is a major challenge facing natural orifice transluminal endoscopic surgery (NOTES).Objective: To evaluate a hydrogen (H_2)-based leak test for assessment of transluminal-access closure integrity after NOTES procedures.Setting: Nine acute porcine experiments.Design and Intervention: After gastric-wall puncture and balloon dilation, peritoneoscopy was performed, followed by transmural closure of the gastric opening. The animals were randomly assigned to complete or incomplete closure groups. The H_2 leak test was performed by using 1000 mL of 4% H_2 gas mixture and the Hydrogen Leak Detector H_2000+. The animals were then euthanized for a methylene blue (MB) test of gastric closure integrity.Main Outcome Measurement: Intraperitoneal H_2 concentration after gastric insufflation with H_2.Results: The H_2 leak test was quick and easy. Intraperitoneal H_2 concentrations in parts per million in both groups were similar at baseline (mean +- SD, 0.18 +- 0.29 parts per million [ppm] vs 0.22 +- 0.35 ppm, P = .97) and after balloon dilation (414.8 +- 198.5 ppm vs 601.3 +- 116.1 ppm, P > .99). Postclosure intraperitoneal H_2 concentrations dropped to 0.01 +- 0.77 ppm in the complete-closure group, similar (P = .81) to matched-pairs preopening levels and significantly lower than in the incomplete-closure group (162.0 +- 83-0 ppm, P < .02). On necropsy, the MB test was negative in all 5 animals of the complete-closure group and positive in all 4 animals of the incomplete-closure group. A cutoff of 25 ppm in intraperitoneal H_2 concentration after closure gave 100% sensitivity, specificity, and positive and negative predictive values for MB leakage.Limitations: Nonsurvival animal experiments.Conclusions: The H_2 leak test is highly accurate for detection of leakage after NOTES procedures and could become a substitute for currently used MB leak tests.
机译:None

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号