...
首页> 外文期刊>Abdominal radiology. >Diurnal variation of major error rates in the interpretation of abdominal/pelvic CT studies
【24h】

Diurnal variation of major error rates in the interpretation of abdominal/pelvic CT studies

机译:腹部/骨盆CT研究解释中重大误差率的昼夜变化

获取原文
获取原文并翻译 | 示例
           

摘要

Rationale and objective Variation of visual selective attention through the day has been demonstrated in several arenas of human performance, including radiology. It is uncertain whether this variation translates to an identifiable diurnal pattern of error rates for radiology interpretation. The purpose of this study was to attempt to identify particular days of the week and times of the day when radiologists might be most prone to error. Materials and methods Abdomen/pelvis CT studies containing at least one major error were collected from a 10-year period from the quality assurance (QA) database at our institution. A major error was defined as a missed finding that had altered management in a way potentially detrimental to the patient. The identified studies were categorized by the day of the week and hour of the day that the study was interpreted. Study volume data over this same period was also obtained by day of the week and time of day, so to normalize the data based on case volume. Standard errors of the volume-adjusted error rates were obtained based on the binomial distribution. The null hypothesis of constant error rates over time was tested using a weighted logistic regression model with linear time as predictor. Results A total of 252 major errors were identified. More errors were made on Monday than on any other day of the week (n = 58). Major error rates increased through the mid to late morning (9 am to 12 pm), and then decreased progressively through the afternoon until 4 pm, when a rise in the error rate was seen. This pattern persisted when error rates were normalized by study volume within each hour. Overall tests of time-constancy of error rates by day and hour were statistically significant (bothp-values < 0.001). Conclusion Our study shows that error rates in abdominal CT do seem to vary with time of day and day of the week. During the workweek, error rates were highest in the late morning and at the close of the workday, and greater on Mondays than other days.
机译:None

著录项

  • 来源
    《Abdominal radiology.》 |2021年第4期|共6页
  • 作者单位

    Univ Wisconsin Sch Med Dept Radiol E3-311 Clin Sci Ctr 600 Highland Ave MC 3252 Madison WI;

    Univ Wisconsin Dept Biostat &

    Med Informat Sch Med 600 Highland Ave Madison WI 53792 USA;

    Cent Illinois Radiol Associates Ltd 111 Oakwood Rd East Peoria IL 61611 USA;

    Univ Wisconsin Sch Med Dept Radiol E3-311 Clin Sci Ctr 600 Highland Ave MC 3252 Madison WI;

    Univ Wisconsin Sch Med Dept Radiol E3-311 Clin Sci Ctr 600 Highland Ave MC 3252 Madison WI;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 内科学;
  • 关键词

    Diurnal variation; Error; CT;

    机译:昼夜变异;错误;CT;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号