首页> 外文期刊>Analytical chemistry >Capillary LC-MS2 at the attomole level for monitoring and discovering endogenous peptides in microdialysis samples collected in vivo
【24h】

Capillary LC-MS2 at the attomole level for monitoring and discovering endogenous peptides in microdialysis samples collected in vivo

机译:处于毛细管状态的毛细管LC-MS2用于监测和发现体内收集的微透析样品中的内源肽

获取原文
获取原文并翻译 | 示例
       

摘要

Fused-silica capillary LC columns (25-mum i.d.) with 3-mum-i.d. integrated electrospray emitters interfaced to a quadrupole ion trap mass spectrometer were evaluated for high-sensitivity LC-MS2. Column preparation involved constructing frits by in situ photopolymerization of glycidyl methacrylate and trimethylolpropane trimethacrylate, preparing the electrospray emitter by pulling the column outlet to a fine tip with a CO2 laser puller, and slurry-packing the column with 5-mum reversed-phase particles. Large-volume injections were facilitated by an automated two-pump system that allowed high-flow rates for sample loading and low-flow rates for elution. Small electrospray emitters, low elution flow rates, and optimization of gradient steepness allowed a detection limit of 4 amol, corresponding to 2 pM for 1.8 muL injected on-column, for a mixture of peptides dissolved in artificial cerebral spinal fluid. The system was coupled on-line to microdialysis sampling and was used to monitor and discover endogenous neuropeptides from the globus pallidus of anesthetized. male Sprague-Dawley rats. Time-segmented MS2 scans enabled simultaneous monitoring of Met-enkephalin, Leu-enkephalin, and unknown peptides. Basal dialysate levels of Met-enkephalin and Leu-enkephalin were 60 +/- 30 and 70 +/- 20 pM while K-(+)-stimulated levels were 1900 +/- 500 and 1300 +/- 300 pM, respectively (n = 7). Data-dependent and time-segmented MS2 scans revealed several unknown peptides that were present in dialysate. One of the unknowns was identified as peptide I1-10 (SPQLEDEAKE), a novel product of preproenkephalin A processing, using MS2, MS3, and database searching.
机译:熔融石英毛细管LC色谱柱(内径25毫米)和内径3毫米评估了与四极离子阱质谱仪连接的集成电喷雾发射器的高灵敏度LC-MS2。色谱柱的制备涉及通过甲基丙烯酸缩水甘油酯和三羟甲基丙烷三甲基丙烯酸酯的原位光聚合来构建玻璃料,通过使用CO2激光拉拔器将色谱柱出口拉至细尖端来制备电喷雾发射器,以及将色谱柱与5μm反相颗粒进行淤浆填充。自动化的两泵系统促进了大批量进样,该系统允许高流速上样和洗脱低流速。较小的电喷雾发射器,较低的洗脱流速以及优化的梯度陡度,允许将溶解于人工脑脊髓液中的肽混合物的检测限设为4 amol,相当于1.8μL柱上注射的2 pM。该系统在线耦合至微透析采样,并用于监测和发现来自麻醉的苍白球的内源性神经肽。雄性Sprague-Dawley大鼠。按时间分段的MS2扫描可同时监测Met-脑啡肽,Leu-脑啡肽和未知肽。 Met-脑啡肽和Leu-脑啡肽的基础透析液水平分别为60 +/- 30和70 +/- 20 pM,而K-(+)刺激的水平分别为1900 +/- 500和1300 +/- 300 pM(n = 7)。数据依赖性和时间分段的MS2扫描显示了透析液中存在的几种未知肽。未知数之一被鉴定为肽I1-10(SPQLEDEAKE),这是前脑啡肽A加工的新产物,使用MS2,MS3和数据库搜索。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号