首页> 外文期刊>Journal of Infrared, Millimeter and Terahertz Waves >Design and Calibration of a mm-Wave Personal Exposure Meter for 5G Exposure Assessment in Indoor Diffuse Environments
【24h】

Design and Calibration of a mm-Wave Personal Exposure Meter for 5G Exposure Assessment in Indoor Diffuse Environments

机译:毫米漫射环境下5G曝光评估的MM波个人曝光仪的设计与校准

获取原文
获取原文并翻译 | 示例
           

摘要

For the first time, a mm-wave personal exposure meter (mm-PEM) for the 5th generation of mobile networks (5G) exposure assessment in indoor diffuse fields is presented. The design is based on simulations and on-phantom calibration measurements in a mm-wave reverberation chamber (RC) at 60 GHz. The mm-PEM consists of an array of nine antennas on the body. Using the mm-PEM, the incident power density (IPD) is measured in the unloaded RC, for the antenna(s) on the phantom and RC loaded with phantom. The uncertainty of the mm-PEM is then determined in terms of its response, which is defined as the ratio of antenna aperture for the above measurement scenarios. Using nine antennas, the designed meter has a response of 1.043 (0.17 dB) at 60 GHz, which is very close to 1 (0 dB), the desired ideal response value. The mm-PEM measured an IPD of 96.6 W m(-2) at 60 GHz in the RC, for an input power of 1 W. In addition, the average absorption cross-section of the phantom is determined as 225 cm(2), which is an excellent agreement with its physical dimensions.
机译:首次,介绍了在室内漫射场中第5代移动网络(5G)曝光评估的MM波个人曝光仪表(MM-PEM)。该设计基于MM波混响室(RC)的模拟和幻影校准测量,在60 GHz。 MM-PEM由身体上的九个天线数组组成。使用MM-PEM,在卸载的RC中测量入射功率密度(IPD),用于幻像上的天线和幻影的RC。然后根据其响应确定MM-PEM的不确定性,其被定义为上述测量场景的天线孔径的比率。使用九个天线,设计的仪表的响应在60 GHz处为1.043(0.17 dB),非常接近1(0 dB),所需的理想响应值。 MM-PEM在RC中的60GHz测量96.6WM(-2)的IPD,用于输入功率为1W。此外,体模的平均吸收横截面确定为225cm(2) ,这是一种与其物理尺寸的极好协议。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号