Studies on Explosion Flow Distribution and Personnel Protection in the Subway Station

机译:地铁站爆炸流动分布与人员保护研究

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The subway station is an easy target for terrorists. In this paper, AUTODYN software is used to simulate the characteristics of shock wave propagation in the subway station. Further, the effects of walls, standing columns and stairs on the shock wave propagation are analyzed quantitatively by setting reference points in the subway station. According to the over-pressure distribution of the explosion at subway station, the casualty distances and the favorable positions for personnel to hide are determined. The results show that the shock wave in the subway station is affected not only by the reflection of the whole structure, but also by the diffraction and local reflection of the platform columns. Due to the pressure relief on the shock wave by the stair exit, the overpressure peak on the stair slope is greater than those at other locations near the stairs at the same explosion distance.
机译:地铁站是恐怖分子的一个简单目标。 在本文中,Autodyn软件用于模拟地铁站中冲击波传播的特征。 此外,通过在地铁站中设置参考点来定量地分析壁,驻距和楼梯上的墙壁对冲击波传播的影响。 根据地铁站爆炸的过压分布,确定伤亡距离和人员藏匿的良好位置。 结果表明,地铁站中的冲击波不仅受到整个结构的反射影响,还受到平台柱的衍射和局部反射的影响。 由于楼梯出口对冲击波上的减压,楼梯上的过压峰值大于同一爆炸距离附近楼梯附近的其他地点的峰值。