Performance of a photostimulable storage phosphor digital system with or without the sharpen filter and cone beam CT for detecting approximal enamel subsurface demineralization

机译:具有或没有锐化滤光片和锥形光束CT的光估量存储磷光体数字系统的性能,用于检测近似搪瓷地下脱矿质

获取原文
获取原文并翻译 | 示例

摘要

Objectives: The aim of this study was to assess the performance of photostimulable storage phosphor (PSP) radiographs with or without using the sharpen filter and cone beam CT (CBCT) for detecting enamel subsurface demineralization. Methods: Enamel subsurface demineralization was induced on one of the approximal surfaces of 120 sound human teeth. Standardized images of all teeth were acquired after the demineralization phase using the Digora? Optime (Orion Corp./Soredex, Helsinki, Finland) (PSP) and the i-CAT? (Imaging Sciences International, Hatfield, PA) (CBCT) systems. Three calibrated observers interpreted the images using a five-point scale (1, demineralization definitely absent; 2, demineralization probably absent; 3, unsure; 4, demineralization probably present; and 5, demineralization definitely present). Diagnoses were validated by cross-sectional microhardness profiling in the test areas of the approximal surfaces. Interobserver agreement was analysed using kappa statistics. Accuracy was estimated by the areas under the receiver operating characteristic curves (Az), which were compared using the Kruskal-Wallis test (α55%). Results: Interobserver agreement was higher for CBCT (κ=0.7-0.8), followed by sharpen-filtered (κ=0.6-0.7) and original (κ=0.5-0.6) images. CBCT presented the highest accuracy value (Az=0.897) compared with the original (Az=0.792) and sharpen-filtered (Az = 0.712) images. However, no statistical differences were observed between the imaging modalities (p= 0.0794). Conclusions: It can be concluded that PSP radiographs with or without using the sharpen filter and the CBCT images may be useful adjuncts for detecting subtle approximal enamel demineralization.
机译:目的:本研究的目的是评估使用锐化过滤器和锥形梁CT(CBCT)的光激销量储存​​磷光体(PSP)X光片的性能,用于检测牙釉质地下脱矿质。方法:在120个声音人体牙齿的一个近似表面上引起搪瓷地下脱矿质。使用Digora的脱矿相位后,在脱矿相位后获得所有牙齿的标准化图像? Optime(Orion Corp./soredex,赫尔辛基,芬兰)(PSP)和I-Cat? (映像科学国际,Hatfield,PA)(CBCT)系统。三个校准的观察者使用五点比例解释了图像(1,脱矿质肯定缺席; 2,脱矿质可能缺席; 3,不确定; 4,脱矿质可能存在; 5,脱矿质肯定存在)。通过近似表面的测试区域中的横截面显微硬度分析验证诊断。使用Kappa统计分析Interobserver协议。通过接收器操作特性曲线(AZ)下的区域估计了准确性,该区域使用Kruskal-Wallis测试(α55%)进行比较。结果:CBCT(κ= 0.7-0.8)的Interobserver协议更高,然后锐化过滤(κ= 0.6-0.7)和原始(κ= 0.5-0.6)图像。 CBCT呈现了与原始(AZ = 0.792)相比的最高精度值(AZ = 0.897),并锐化过滤(AZ = 0.712)图像。然而,在成像模式之间没有观察到统计学差异(P = 0.0794)。结论:可以得出结论,具有或不使用锐化滤波器的PSP X线片和CBCT图像可以是有用的辅助,用于检测微妙的近似搪瓷脱矿质。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号