Harmonics reduction in standalone DFIG-DC system by shunt active filter controlled in stator flux reference frame

机译:定子通量参考框架中的分流有源滤波器独立DFIG-DC系统的谐波减少

获取原文
获取原文并翻译 | 示例
       

摘要

The presence of diode rectifier in standalone Doubly Fed Induction Generator-Direct Current (DFIG-DC) system leads to considerable current, voltage and torque harmonics and requires reactive power from the machine. A unique shunt active filter arrangement is proposed for addressing these requirements. The DC Link of DFIG-DC itself acts as input to shunt active filter and there is no requirement of creating and regulating a separate one. Since the stator flux reference frame is known in FOC of DFIG-DC system; the same can be used as PLL for the generation of current references for harmonics and reactive compensation in active filter control scheme. Hence, the AC voltage sensing is not needed in the proposed active filter control. In this paper, it is shown that current, voltage and torque harmonics are reduced with the help of shunt active filter, which have lower rating compared to the rotor side converter. The proposed scheme is verified by detailed experiments on a 5.5 kW slip-ring induction machine.
机译:独立的双馈电流发电机 - 直流(DFIG-DC)系统的二极管整流器的存在导致相当大的电流,电压和扭矩谐波,并且需要从机器的无功功率。提出了一种独特的分流式有源滤波器装置,用于解决这些要求。 DFIG-DC本身的直流链路充当分流有源滤波器的输入,并且不需要创建和调节单独的输入。由于定子磁通参考框架在DFIG-DC系统的FOC中是已知的;这同样可以用作PLL,用于产生有源滤波器控制方案中的谐波和反应补偿的电流参考。因此,在所提出的主动滤波器控制中不需要交流电压感测。在本文中,示出了利用分流有源滤波器的电流,电压和扭矩谐波减小,与转子侧转换器相比具有较低的额定值。通过在5.5 kW滑动环感应机上进行详细实验验证所提出的方案。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号