Forged composites of raw particulate unsintered hydroxyapatite/poly-L-lactide (F-u-HA/PLLA) devices possess high mechanical strength, bioactivity, and radio-opacity. The aim of this study was to assess the efficacy of F-u-HA/PLLA screws in the treatment of lateral tibial condylar fractures. From January 2005 to December 2010, a total of 7 patients with displaced closed lateral tibial condylar fractures (Schatzker type II) were treated using F-u-HA/PLLA screws. Open reduction and internal fixation was performed using 2 or 3 F-u-HA/PLLA screws. After surgery, weight bearing was not allowed for 6 weeks. Range of motion exercise was initiated after removal of the plaster splint. Radiographs were evaluated for fracture healing, joint depression, and the radio-opacity of F-u-HA/PLLA screws. Clinical outcomes and postoperative complications were also assessed. Average follow-up was 44 months. All fractures were successfully healed. Average values for joint depression were 4.7 mm (range, 2-9 mm) preoperatively, 0.4 mm (range, 0-1 mm) postoperatively, and 0.4 mm (range, 0-1 mm) at final follow-up. Whole shadows of F-u-HA/PLLA screws were observed during the follow-up period. Breakage of screws, osteolysis, and a radiolucent zone around the screws were not observed at final follow-up. Average knee flexion and extension were 134 degrees (range, 110 degrees to 150 degrees) and -1 degrees (range, -10 degrees to 0 degrees), respectively. No patient had wound infection, late aseptic tissue response, or foreign body reaction postoperatively. None of the patients reported pain at final follow-up. These results suggest that F-u-HA/PLLA screws could be an alternative option for the treatment of lateral tibial condylar fractures.
机译:原料颗粒状未烧结的羟基磷灰石/聚-L-丙交酯(F-U-HA / PLLA)器件的锻造复合材料具有高机械强度,生物活性和无透明度。本研究的目的是评估F-U-HA / PLLA螺钉在横向胫骨髁突骨骨折治疗中的功效。从2005年1月到2010年12月,使用F-U-HA / PLLA螺钉治疗总共7例患有流离失所的侧胫骨髁骨折(Schatzker II类)。使用2或3 F-U-HA / PLLA螺钉进行开放式和内部固定。手术后,重量轴承不允许6周。在移除膏药夹板后启动运动锻炼范围。评估裂隙照片的F-U-HA / PLLA螺钉的骨折愈合,关节凹陷和无透明度。还评估了临床结果和术后并发症。平均随访时间为44个月。所有骨折都成功愈合。在最终随访时,关节凹陷的平均值为4.7毫米(范围,2-9毫米),0.4mm(范围为0-1 mm),最终随访0.4mm(范围为0-1毫米)。在随访期间观察到F-U-HA / PLLA螺钉的整个阴影。在最终随访时未观察到螺钉,骨溶解和螺钉周围的透射区域的破损。平均膝关节屈曲和延伸分别为134度(范围,110度至150度),分别为-1度(范围,-10度至0度)。术后没有患者没有伤口感染,晚期无菌组织反应或异物反应。没有患者在最终随访中报告过疼痛。这些结果表明F-U-HA / PLLA螺钉可以是治疗侧胫骨髁骨折的替代选择。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号