Visual and optical performance and quality of life after implantation of posterior chamber phakic intraocular lens

机译:后腔护目镜眼透镜植入后的视觉和光学性能和寿命。

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose: To evaluate visual, optical, and quality of life (QoL) outcomes and intercorrelations after bilateral implantation of posterior chamber phakic intraocular lenses. Methods: Twenty eyes with high to moderate myopia of 10 patients that underwent PRL implantation (Phakic Refractive Lens, Carl Zeiss Meditec AG) were examined. Refraction, visual acuity, photopic and low mesopic contrast sensitivity (CS) with and without glare, ocular aberrations, as well as QoL outcomes (National Eye Institute Refractive Error Quality of Life Instrument-42, NEI RQL-42) were evaluated at 12 months postoperatively. Results: Significant improvement in uncorrected (UDVA) and best-corrected distance (CDVA) visual acuities were found postoperatively (p < 0.01), with significant reduction in spherical equivalent (p < 0.01). Low mesopic CS without glare was significantly better than measurements with glare for 1.5, 3, and 6 cycles/degree (p < 0.01). No significant correlations between higher order root mean square (RMS) with CDVA (r = -0.26, p = 0.27) and CS (r ≤ 0.45, p ≥ 0.05) were found. Postoperative binocular photopic CS for 12 cycles/degree and 18 cycles/degree correlated significantly with several RQL-42 scales. Glare index correlated significantly with CS measures and scotopic pupil size (r = -0.551, p = 0.04), but not with higher order RMS (r = -0.02, p = 0.94). Postoperative higher order RMS, postoperative primary coma and postoperative spherical aberration was significant higher for 5-mm pupil diameter (p < 0.01) compared with controls. Conclusions: Correction of moderate to high myopia by means of PRL implantation had a positive impact on CS and QoL. The aberrometric increase induced by the surgery does not seem to limit CS and QoL. However, perception of glare is still a relevant disturbance in some cases possibly related to the limitation of the optical zone of the PRL.
机译:目的:评估双侧植入后室象形学眼内晶状体后的视觉,光学和寿命的质量(QOL)结果和互相关性。方法:20只眼睛高于高于中度近视的10名患者,接受了PRL植入(Phakic折射镜,Carl Zeiss Meditec Ag)。在12个月内评估折射,眼镜和没有眩光,眼镜和QOL结果(Life Instrults-42,Nei RQL-42)的QoL结果(Nei RQL-42)的折射率术后。结果:术后(P <0.01)发现未校正(UDVA)和最佳校正距离(CDVA)视觉缩窄的显着改善,具有显着降低球形当量(P <0.01)。没有眩光的低成本Cs明显优于1.5,3和6个循环/程度的眩光(P <0.01)。未发现高阶均方方(RMS)与CDVA(r = -0.26,p = 0.27)和cs(r≤0.45,p≥0.05)之间的显着相关性。术后双目光学CS为12个循环/度和18个循环/程度,几个RQL-42尺度显着相关。眩光指数随着CS测量和Scotopic瞳孔尺寸而显着相关(R = -0.551,P = 0.04),但不具有更高的阶RMS(r = -0.02,p = 0.94)。与对照相比,术后高阶rms,术后初级彗态和术后球形畸变显着较高(P <0.01)。结论:通过PRL植入矫正中度至高近视对CS和QOL产生正影响。手术诱导的恶性增加似乎没有限制CS和QOL。然而,在可能与PRL光学区的限制有关的情况下,对眩光的感知仍然是相关的干扰。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号