Microwave-assisted acid decomposition, direct dilution in kerosene, and oil-in-water emulsion were evaluated as lubricating oil pretreatment procedures for Cu, Cr, Fe, Ni, Pb, Sb, and Zn determination by High-Resolution Continuum Source Flame Atomic Absorption Spectrometry (HR-CS FAAS). For wet digestion, results were compared with those obtained by Flame Atomic Absorption Spectrometry (FAAS). The ultrasound probe used in emulsions sonication contaminated samples with Cr, although better results have been observed for the other six elements in this condition. In general, recovery percentages ranging from 81-106%(Cu), 80-107%(Cr), 85-114%(Fe), 82-116%(Ni), 86-117%(Pb), 85-115%(Sb), and 81-114%(Zn) were obtained. The HR-CS FAAS showed to be faster and more sensitive than FAAS.
机译:通过高分辨率连续源火焰原子吸收评价微波辅助酸分解,煤油中的直接稀释和水乳液和水包油乳液。通过高分辨率连续源火焰原子吸收润滑油预处理程序作为润滑油预处理程序。 光谱法(HR-CS FAAS)。 对于湿法消化,将结果与火焰原子吸收光谱法(FAAS)获得的结果进行了比较。 乳液中使用的超声探头与CR的污染污染样品,但在这种情况下对其他六种元素观察到更好的结果。 通常,恢复百分比范围为81-106%(Cu),80-107%(Cr),85-114%(Fe),82-116%(Ni),86-117%(Pb),85-115 获得%(Sb)和81-114%(Zn)。 HR-CS FAAS显示比FAAS更快,更敏感。