首页> 外文期刊>Circulation journal >Abnormal end-tidal PO 2 and PCO 2 at the anaerobic threshold correlate well with impaired exercise gas exchange in patients with left ventricular dysfunction
【24h】

Abnormal end-tidal PO 2 and PCO 2 at the anaerobic threshold correlate well with impaired exercise gas exchange in patients with left ventricular dysfunction

机译:在厌氧阈值下异常的潮汐PO 2和PCO 2与左心室功能障碍患者的运动气体交换有损害

获取原文
获取原文并翻译 | 示例
           

摘要

Background: The aim of the present study was to compare the end-tidal O 2 pressure (PETO 2) to end-tidal CO 2 pressure (PETCO 2) in cardiac patients during rest and during 2 states of exercise: at anaerobic threshold (AT) and at peak. The purpose was to see which metabolic state, PETO 2 or PETCO 2, best correlated with exercise limitation. Methods and Results: Thirty-eight patients with left ventricular (LV) ejection fraction 40% underwent cardiopulmonary exercise testing (CPX). PETO 2 and PETCO 2 were measured during CPX, along with peak O 2 uptake (VO 2), AT, slope of the increase in ventilation (VE) relative to the increase in CO 2 output (VCO 2) (VE vs. VCO 2 slope), and the ratio of the increase in VO 2 to the increase in work rate (ΔVO 2/ΔWR). Both PETO 2 and PETCO 2 measured at AT were best correlated with peakVO 2, AT, ΔVO 2/ΔWR and VE vs. VCO 2 slope. PETO2 at AT correlated with reduced peak VO 2 (r=-0.60), reduced AT (r=-0.52), reduced ΔVO 2/ΔWR (r=-0.55) and increased VE vs. VCO 2 slope (r=0.74). PETCO 2 at AT correlated with reduced peak VO 2 (r=0.67), reduced AT (r=0.61), reduced ΔVO 2/ΔWR (r=0.58) and increased VE vs. VCO 2 slope (r=-0.80). Conclusions: PETCO 2 and PETO 2 at AT correlated with peak VO 2, AT and ΔVO 2/ΔWR, but best correlated with increased VE vs. VCO 2 slope. PETO 2 and PETCO 2 at AT can be used as a prime index of impaired cardiopulmonary function during exercise in patients with LV failure.
机译:背景:本研究的目的是在休息期间和2个运动状态期间将末端O 2压力(PETO 2)与心脏病患者的末端CO 2压力(PETCO 2)进行比较:在anaerobic阈值下(在)和峰值。目的是看到哪种代谢状态,PETO 2或PETCO 2,与运动限制最好相关。方法和结果:三十八名左心室(LV)射血馏分患者进行突出的术语术术术语(CPX)。在CPX期间测量PETO 2和PETCO 2,以及相对于CO 2输出(VCO 2)增加(VCO 2)的增加(VCO 2)(VS.VCO 2斜率),VO 2的增加与工作速率增加(ΔVO2/ΔWR)的比率。在AT以峰值2,ΔVO2 /ΔWR和VCO 2斜坡上最佳地与峰值2,ΔVO2 /ΔWR和VCO 2斜率相关的PETO 2和PETCO 2最佳。在与降低的峰值VO 2(R = -0.60)相关的PETO2,降低(r = -0.52),减少ΔVO2 /ΔWR(r = -0.55)和增加VCO 2斜率(r = 0.74)。在与降低的峰值VO 2(r = 0.67)相关的Petco 2,减少(r = 0.61),减少ΔVO2 /ΔWr(r = 0.58),并且Vco 2斜率增加(r = -0.80)。结论:Petco 2和PETO 2与峰值VO 2,AT和ΔVO2 /ΔWR相关,但与VCO 2斜率的增加最佳。 PETO 2和Petco 2可以用作LV衰竭患者运动期间心肺功能受损的损伤素指数。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号