...
首页> 外文期刊>Radiology >Variability in interpretive performance at screening mammography and radiologists' characteristics associated with accuracy.
【24h】

Variability in interpretive performance at screening mammography and radiologists' characteristics associated with accuracy.

机译:筛选乳房X线照相术和放射科学家特性的解释性能的可变性。

获取原文
获取原文并翻译 | 示例

摘要

PURPOSE: To identify radiologists' characteristics associated with interpretive performance in screening mammography. MATERIALS AND METHODS: The study was approved by institutional review boards of University of Washington (Seattle, Wash) and institutions at seven Breast Cancer Surveillance Consortium sites, informed consent was obtained, and procedures were HIPAA compliant. Radiologists who interpreted mammograms in seven U.S. regions completed a self-administered mailed survey; information on demographics, practice type, and experience in and perceptions of general radiology and breast imaging was collected. Survey data were linked to data on screening mammograms the radiologists interpreted between January 1, 1998, and December 31, 2005, and included patient risk factors, Breast Imaging Reporting and Data System assessment, and follow-up breast cancer data. The survey was returned by 71% (257 of 364) of radiologists; in 56% (205 of 364) of the eligible radiologists, complete data on screening mammograms during the study period were provided; these data were used in the final analysis. An evaluation of whether the radiologists' characteristics were associated with recall rate, false-positive rate, sensitivity, or positive predictive value of recall (PPV(1)) of the screening examinations was performed with logistic regression models that were adjusted for patients' characteristics and radiologist-specific random effects. RESULTS: Study radiologists interpreted 1 036 155 screening mammograms; 4961 breast cancers were detected. Median percentages and interquartile ranges, respectively, were as follows: recall rate, 9.3% and 6.3%-13.2%; false-positive rate, 8.9% and 5.9%-12.8%; sensitivity, 83.8% and 74.5%-92.3%; and PPV(1), 4.0% and 2.6%-5.9%. Wide variability in sensitivity was noted, even among radiologists with similar false-positive rates. In adjusted regression models, female radiologists or fellowship-trained radiologists had significantly higher recall and false-positive rates (P < .05, all). Fellowship training in breast imaging was the only characteristic significantly associated with improved sensitivity (odds ratio, 2.32; 95% confidence interval: 1.42, 3.80; P < .001) and the overall accuracy parameter (odds ratio, 1.61; 95% confidence interval: 1.05, 2.45; P = .028). CONCLUSION: Fellowship training in breast imaging may lead to improved cancer detection, but it is associated with higher false-positive rates.
机译:目的:鉴定筛选乳房X线摄影中与解释性表现相关的放射科学专业。材料和方法:研究由华盛顿大学(西雅图,洗涤)和七个乳腺癌监测联盟网站的机构批准,获得了知情同意,程序符合HIPAA。解释乳房X线图的放射科医师在七个美国地区完成了一个自我管理的邮寄调查;收集有关人口统计学,实践类型和经验和一般放射学和乳房成像的认识的信息。调查数据与筛选乳房X线照片的数据相关联,解释了1998年1月1日至2005年12月31日,并包括患者危险因素,乳房成像报告和数据系统评估以及随访的乳腺癌数据。该调查由71%(364名)放射科学家返回;在符合条件放射科医生的56%(第364名中,共分364名中,共有564个),提供了在研究期间筛选乳房X线照片的完整数据;这些数据用于最终分析。评价放射药剂的特性是否与召回率,假阳性率,敏感性或核率(PPV(1))进行筛选检查的验证(PPV(1))与患者特征调整的逻辑回归模型进行和放射科医生特定的随机效果。结果:研究放射科学家解释为1 036 155筛选乳房X光图;检测到4961个乳腺癌。中位数百分比分别如下:召回率,9.3%和6.3%-13.2%;假阳性率,8.9%和5.9%-12.8%;敏感性,83.8%和74.5%-92.3%;和PPV(1),4.0%和2.6%-5.9%。甚至在具有类似假阳性率的放射科医生中,注意到灵敏度的广泛变化。在调整后的回归模型中,女性放射学家或培训的放射学家的召回和假阳性率显着高(P <.05,全部)。乳腺成像的奖学金训练是唯一与改善的敏感性有显着相关的特征(差距比例,2.32; 95%:1.42,3.80; p <.001)和整体精度参数(赔率比,1.61; 95%置信区间: 1.05,2.45; p = .028)。结论:乳腺成像的奖学金训练可能导致癌症检测改善,但它与较高的假阳性率相关。

著录项

  • 来源
    《Radiology》 |2009年第3期|共11页
  • 作者

    Elmore JG; Jackson SL; Abraham L;

  • 作者单位

    Department of Medicine University of Washington School of Medicine Harborview Medical Center 325 Ninth Ave Box 359780 Seattle WA 98104-2499 USA.;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 放射医学;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号