PURPOSE OF REVIEW: Dual-energy X-ray absorptiometry is now widely adopted for the measurement of the fat, fat-free soft tissue and bone mineral compartments of the body. Whereas it is regarded by many as a reference technique for such measurements, it is not without limitations. Inter and intra-manufacturer differences have been areas of concern. This review focuses on recent literature addressing these areas and the issue of validity. RECENT FINDINGS: Body composition measurements using newer generation dual-energy X-ray absorptiometry machines compared between different manufacturers and compared with earlier instruments continue to show differences that may be unacceptable, particularly for investigators upgrading their machines or involved in multicentre studies using different machines. In terms of validity, significant deviations at a group level are reported when compared with reference four-component models, and perhaps more importantly, wide limits of agreement are seen that are a concern for the interpretation of results at an individual level. SUMMARY: It is important that investigators recognize the limitations of dual-energy X-ray absorptiometry technology in the interpretation of their results. There is a continuing need both for inter-machine comparisons and validation studies against accepted criterion methods, particularly as new software or technological changes are introduced. Such studies permit the development of translation equations for the cross-calibration of devices, and may be vital for cross-sectional studies. For longitudinal studies in many populations, dual-energy X-ray absorptiometry is without question a valuable technique for the measurement of compositional changes, both at the total body and regional levels.
机译:审查的目的:双能量X射线吸收法现已广泛用于测量人体的脂肪,无脂肪的软组织和骨矿物质室。尽管许多人将其视为此类测量的参考技术,但并非没有限制。制造商之间和内部的差异一直是令人关注的领域。本文的重点是针对这些领域和有效性问题的最新文献。最近的发现:在不同制造商之间进行比较,并与早期仪器进行比较,使用新一代双能X射线吸收仪进行的身体成分测量仍然显示出可能无法接受的差异,尤其是对于研究人员升级其机器或参与使用不同机器进行多中心研究的情况。在有效性方面,与参考的四部分模型相比,报告了组水平上的显着偏差,也许更重要的是,观察到广泛的一致性限制,这是在单个水平上解释结果的关注点。摘要:研究人员在解释其结果时必须认识到双能X射线吸收仪技术的局限性,这一点很重要。持续需要针对公认标准方法的机器间比较和验证研究,特别是在引入新软件或技术变化时。这样的研究允许开发用于设备交叉校准的转换方程,并且对于横截面研究可能至关重要。对于许多人群的纵向研究而言,双能量X射线吸收法无疑是一种用于测量全身和区域水平组成变化的有价值的技术。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号