The effect of fibre concentration, temperature and mould thickness on tensile strength of single- and double-gated injection-moulded polypropylene copolymer reinforced with 0, 10, 20, 30 and 40 wt% short glass fibre was studied at a fixed strain-rate of 7.58 x 10(-3) s(-1) between 23 and 100 A degrees C. It was found that tensile strength of single-gated mouldings, sigma(c), increased with increasing volume fraction of fibres, I center dot(f) in a nonlinear manner and decreased with increasing temperature in a linear manner. However, for I center dot(f) values in the range 0-10% a simple additive rule-of-mixtures adequately described the variation of sigma(c) with I center dot(f) over the entire temperature range 23-100 A degrees C studied here. Tensile strength of double-gated mouldings like their single-gated counterparts decreased linearly with increasing temperature. The presence of weldlines significantly reduced tensile strength of double-gated composite mouldings but had little effect on tensile strength of the matrix. Weldline integrity factor, F (sigma), defined as weldline strength divided by unweld strength, decreased with increasing I center dot(f) but increased with increasing temperature. A linear dependence was found between F (sigma) and temperature. Mould thickness had no significant effect upon weld and unweld tensile strengths and consequently had no significant effect upon weldline integrity factor.
机译:研究了纤维浓度,温度和模具厚度对0、10、20、30和40 wt%短玻璃纤维增​​强的单门和双门注塑聚丙烯共聚物的拉伸强度的影响。在23至100 A摄氏度之间为7.58 x 10(-3)s(-1)。发现单浇口成型品的抗拉强度sigma(c)随着纤维体积分数I中心点(f)的增加而增加。 )呈非线性方式,并且随着温度的升高呈线性方式降低。但是,对于I中心点(f)值在0-10%范围内,简单的加法混合法充分描述了在整个温度范围23-100 A中sigma(c)与I中心点(f)的变化。摄氏度在这里学习。像单浇口成型件一样,双浇口成型件的拉伸强度随温度升高而线性降低。焊缝的存在显着降低了双浇口复合成型件的拉伸强度,但对基体的拉伸强度影响很小。焊缝完整性系数F(sigma),定义为焊缝强度除以未焊缝强度,随着I中心点(f)的增加而降低,但随着温度的升高而增加。发现F(西格玛)与温度之间存在线性关系。模具厚度对焊接和未焊接抗拉强度没有显着影响,因此对焊接线完整性因子也没有显着影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号