摘要

Owing to its high toxicity, even at very low concentration, early detection of carbon monoxide (CO) is imperative. We have fabricated sensors comprising gold nanoparticle-loaded cerium oxide (Au-CeO2). The morphology and elemental composition of the sensing material have been characterized using XRD, FESEM, TEM and XPS. The performance of the Au-CeO2 sensors has been studied for the detection of CO in the concentration range of 10-30 ppm in air. The response and recovery transients of conductance have been modeled using two-site Langmuir adsorption kinetics. In the presence of 30 ppm CO, the calculated response times for two energetically different adsorption sites, CeO2 surface and Au/CeO2 interface are 9 s and 7 s, respectively. Finally, an exponential correlation between the gas concentration and the time constants has been derived.
机译:由于其高毒性,即使浓度很低,也必须及早发现一氧化碳(CO)。我们制造了包含金纳米颗粒负载氧化铈(Au-CeO2)的传感器。使用XRD,FESEM,TEM和XPS对传感材料的形貌和元素组成进行了表征。已经研究了Au-CeO2传感器的性能,用于检测空气中10-30 ppm浓度范围内的CO。电导的响应和恢复瞬态已使用两点Langmuir吸附动力学建模。在30 ppm CO的存在下,两个能量上不同的吸附位CeO2表面和Au / CeO2界面的计算响应时间分别为9 s和7 s。最后,得出了气体浓度和时间常数之间的指数关系。