首页> 外文期刊>Investigative ophthalmology & visual science >A new, specular reflection-based, precorneal tear film stability measurement technique in a rabbit model: Viscoelastic increases tear film stability
【24h】

A new, specular reflection-based, precorneal tear film stability measurement technique in a rabbit model: Viscoelastic increases tear film stability

机译:一种新的基于镜面反射的兔模型角膜前泪膜稳定性测量技术:粘弹性可提高泪膜稳定性

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE. To develop a safe, noninvasive, noncontact, continuous in vivo method to measure the dehydration rate of the precorneal tear film and to compare the effectiveness of a viscoelastic agent in maintaining the precorneal tear film to that of a balanced salt solution. METHODS. Software was designed to analyze the corneal reflection produced by the operating microscope's coaxial illumination. The software characterized the shape of the reflection, which became distorted as the precorneal tear film evaporated; characterization was accomplished by fitting an ellipse to the reflection and measuring its projected surface area. Balanced salt solution Plus (BSS+) and a 2% hydroxypropylmethylcellulose viscoelastic were used as the test agents. The tear film evaporation rate was characterized and compared over a period of 20 minutes in 20 eyes from 10 New Zealand white rabbits. RESULTS. The ellipse axes ratio and surface area were found to decrease initially after each application of either viscoelastic or BSS+ and then to increase linearly as the tear film began to evaporate (P < 0.001) for eyes treated with BSS+ only. Eyes treated with BSS+ required 7.5 ± 2.7 applications to maintain sufficient corneal hydration during the 20-minute test period, whereas eyes treated with viscoelastic required 1.4 ± 0.5 applications. The rates of evaporation differed significantly (P < 0.043) between viscoelastic and BSS+. CONCLUSIONS. The shape and surface area of the corneal reflection are strongly correlated with the state of the tear film. Rabbits' corneas treated with viscoelastic remained hydrated significantly longer than corneas treated with BSS+.
机译:目的。为了开发一种安全,无创,非接触,连续的体内方法,以测量角膜前泪膜的脱水率,并比较粘弹性剂在维持角膜前泪膜与平衡盐溶液中的有效性。方法。设计软件来分析手术显微镜同轴照明产生的角膜反射。该软件的特征是反射的形状,随着角膜前泪膜的蒸发,该形状变得失真。通过使椭圆适合反射并测量其投影表面积来完成表征。使用平衡盐溶液Plus(BSS +)和2%羟丙基甲基纤维素粘弹性作为测试剂。在20分钟的时间内,对来自10只新西兰白兔的泪膜蒸发速率进行了表征和比较。结果。对于仅使用BSS +处理的眼睛,发现每次施加粘弹性或BSS +后,椭圆轴比率和表面积都会先减小,然后随着泪膜开始蒸发而线性增加(P <0.001)。用BSS +处理的眼睛需要7.5±2.7的应用,以在20分钟的测试期间保持足够的角膜水合作用,而用粘弹性处理的眼睛需要1.4±0.5的应用。粘弹性和BSS +之间的蒸发速率差异显着(P <0.043)。结论。角膜反射的形状和表面积与泪膜的状态密切相关。粘弹性处理的兔角膜保持水合的时间明显长于BSS +处理的角膜。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号